BACKGROUND AND
OBJECTIVES
Intraoperative adjuncts for the localization of parathyroid glands in parathyroid surgery are limited. The aim of this study is to assess the usefulness of indocyanine green (ICG) near-infrared (NIR) fluorescent imaging in patients undergoing surgery for primary hyperparathyroidism (PHPT).
METHODS
ICG imaging was performed in 33 patients undergoing parathyroidectomy (PTX). Thyroid and parathyroid ICG uptake were assessed and independently verified on a grading scale. Clinical variables were recorded and analyzed for factors associated with ICG uptake.
RESULTS
Of 112 glands identified by naked eye, 104 (92.9%) demonstrated ICG uptake. Concomitant ICG fluorescence was identified in the thyroid in all patients. There was a trend toward increased ICG fluorescence in patients <60 years of age (P = 0.05). A higher degree of fluorescence was seen in patients presenting with pre-operative calcium values >11 mg/dl (P = 0.04) and in those parathyroids larger than 10 mm (P < 0.01). All patients had biochemically proven cure. No patients who underwent subtotal PTX (n = 6) developed postoperative hypoparathyroidism.
CONCLUSION
ICG can reliably localize parathyroid glands during PTX and additionally allow for assessment of parathyroid perfusion in patients undergoing subtotal resection. Concomitant fluorescence of the thyroid gland limits ICG's usefulness in directing the course of PTX. J. Surg. Oncol. 2016;113:771-774. © 2016 Wiley Periodicals, Inc.