Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study.

Knappe Dorit, Vogler Julia, Weimann Jessica, Banas Victor, Yildirim Sevenai, Memenga Felix, Senftinger Juliana, Keil Laura, Ismaili Djemail, Nies Moritz, Rillig Andreas, Willems Stephan, Blankenberg Stefan, Kirchhof Paulus, Metzner Andreas, Sinning Christoph

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: For patients with symptomatic drug-refractory atrial fibrillation (AF), catheter ablation to achieve rhythm control is an important therapeutic option. The atrial mechanical dispersion measured as standard deviation of the time to peak strain (SD-TPS) is associated with the risk of AF recurrence following catheter ablation.

METHODS

The study cohort prospectively enrolled n = 132 consecutive patients with paroxysmal (n = 88) or persistent AF (n = 44) presenting for de novo pulmonary vein isolation (PVI) and followed for 1 year. We related left atrial (LA) volume, LA ejection fraction, SD-TPS, and global longitudinal strain of the left ventricle and clinical variables (sex, age, and type of AF) to AF recurrence.

RESULTS

Kaplan-Meier curves showed higher AF recurrence rate with an increase of SD-TPS with the calculated cut-off of 38.6 ms. Uni- and multivariable Cox regression analysis could show that SD-TPS had the highest relevance regarding AF recurrence with a HR of 1.05 (95% CI, 1.01; 1.09, p = 0.01) and HR of 1.05 (95% CI, 1.01; 1.09, p = 0.02) per 10 ms increase. In the additional analyses for the model including the clinical variables age, sex, and type of AF with paroxysmal or persisting AF, SD-TPS did only show a trend and after adjusting for covariates, SD-TPS showed a HR of 1.04 (95% CI, 0.99; 1.09, p = 0.09) per 10 ms increase.

CONCLUSION

Atrial mechanical dispersion was associated with recurrent AF.

Для цитирования: Knappe Dorit, Vogler Julia, Weimann Jessica, Banas Victor, Yildirim Sevenai, Memenga Felix, Senftinger Juliana, Keil Laura, Ismaili Djemail, Nies Moritz, Rillig Andreas, Willems Stephan, Blankenberg Stefan, Kirchhof Paulus, Metzner Andreas, Sinning Christoph. Association of atrial mechanical dispersion with atrial fibrillation recurrence following catheter ablation: results of the ASTRA-AF pilot study.. Clinical research in cardiology : official journal of the German Cardiac Society. 2024. DOI: 10.1007/s00392-024-02435-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.