Rapid Ultrasonography for Shock and Hypotension Protocol Performed using Handheld Ultrasound Devices by Paramedics in a Moving Ambulance: Evaluation of Image Accuracy and Time in Motion.

Azapoglu Kaymak Burcu, Eksioglu Merve

СтатьяОтозванная публикацияПеревод пока не подготовлен
Источник пометил публикацию как отозванную.

Аннотация

INTRODUCTION

Handheld ultrasound (US) devices have become increasingly popular since the early 2000s due to their portability and affordability compared to conventional devices. The Rapid Ultrasonography for Shock and Hypotension (RUSH) protocol, introduced in 2009, has shown promising accuracy rates when performed with handheld devices. However, there are limited data on the accuracy of such examinations performed in a moving ambulance. This study aimed to assess the feasibility and accuracy of the RUSH protocol performed by paramedics using handheld US devices in a moving ambulance.

OBJECTIVES

The study aimed to examine the performability of the RUSH protocol with handheld US devices in a moving ambulance and to evaluate the accuracy of diagnostic views obtained within an appropriate time frame.

METHODS

A prospective study was conducted with paramedics who underwent theoretical and practical training in the RUSH protocol. The participants performed the protocol using a handheld US device in both stationary and moving ambulances. Various cardiac and abdominal views were obtained and evaluated for accuracy. The duration of the protocol performance was recorded for each participant.

RESULTS

Nine paramedics completed the study, with 18 performances each in both stationary and moving ambulance groups. The accuracy of diagnostic views obtained during the RUSH protocol did not significantly differ between the stationary and moving groups. However, the duration of protocol performance was significantly shorter in the moving group compared to the stationary group.

CONCLUSION

Paramedics demonstrated the ability to perform the RUSH protocol effectively using handheld US devices in both stationary and moving ambulances following standard theoretical and practical training. The findings suggest that ambulance movement does not significantly affect the accuracy of diagnostic views obtained during the protocol. Further studies with larger sample sizes are warranted to validate these findings and explore the potential benefits of prehospital US in dynamic environments.

Для цитирования: Azapoglu Kaymak Burcu, Eksioglu Merve. Rapid Ultrasonography for Shock and Hypotension Protocol Performed using Handheld Ultrasound Devices by Paramedics in a Moving Ambulance: Evaluation of Image Accuracy and Time in Motion.. Prehospital and disaster medicine. 2024. DOI: 10.1017/s1049023x24000426.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.