MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivr148

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2012

Surgical left ventricular radius enlargement by patch insertion on the beating heart: a new experimental aneurysm model.

Gründeman Paul F, van der Spoel Tycho I G, Steendijk Paul, van Slochteren Frebus, Cramer Maarten Jan M, Doevendans Pieter A, Pasterkamp Gerard

СтатьяПоддержка исследования: вне правительства СШАVideo-Audio MediaПеревод пока не подготовлен

Аннотация

We presented a novel experimental aneurysm model for studies in left ventricular (LV) reconstruction techniques and assessed LV function. In eight pigs, the LV radius and geometry were enlarged surgically on the beating heart by inserting an aortic allograft construct. Haemodynamics and LV dimensions were assessed by echocardiography at baseline and under dobutamine stress. Surgery was successfully performed without lethal blood loss or arrhythmias. LV end-diastolic and end-systolic short-axis areas increased from 13.0 ± 1.7 to 17.0 ± 4.3 cm(2) (P = 0.001) and from 4.0 ± 0.9 to 13.0 ± 2.6 cm(2) (P = 0.001), respectively. Stroke volume decreased from 56 ± 11 to 33 ± 16 ml (P = 0.001). Incremental dobutamine infusion concurred with a biphasic response on fractional area shortening. Mitral valve insufficiency ranging from grades 2 to 4 was observed. In the pig, a novel, reproducible aneurysm model for acute cardiac dysfunction was created on the beating heart. Innovative (surgical) strategies for (staged) reconfiguration of the ventricle, e.g. adjustable Dor procedures and stepwise volume restraining cardiac support devices, can be tested for efficacy using this acute model.

Для цитирования: Gründeman Paul F, van der Spoel Tycho I G, Steendijk Paul, van Slochteren Frebus, Cramer Maarten Jan M, Doevendans Pieter A, Pasterkamp Gerard. Surgical left ventricular radius enlargement by patch insertion on the beating heart: a new experimental aneurysm model.. Interactive cardiovascular and thoracic surgery. 2012. DOI: 10.1093/icvts/ivr148.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.