MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00380-014-0512-9

Медицинская библиотека · Heart and vessels · 2014

Impact of secondary hyperparathyroidism on ventricular mass regression after aortic valve replacement for aortic stenosis in hemodialysis-dependent patients.

Takami Yoshiyuki, Tajima Kazuyoshi

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

In hemodialysis (HD)-dependent patients, secondary hyperparathyroidism induces cardiac hypertrophy. This study investigated whether parathyroid hormone (PTH) levels affect the degree of left ventricular (LV) mass regression in HD patients after aortic valve replacement (AVR) for aortic stenosis (AS). We retrospectively obtained preoperative and 2-year postoperative echocardiography and intact PTH measurements in 88 HD patients who underwent AVR, with bioprostheses (n = 35, 40%) and mechanical valves (n = 53, 60%) of effective orifice area >0.80 cm2/m2, between January 1997 and December 2010. The LV mass decreased significantly from 308 ± 88 to 217 ± 68 g at follow-up of 28 ± 4 months after AVR (p < 0.001). The LV mass regression at follow-up was inversely related to preoperative PTH values (R = 0.44, p = 0.001). The LV mass regression at follow-up was significantly smaller in the patients (n = 47) with PTH ≥100 pg/mL than in those (n = 41) with PTH <100 pg/mL throughout the study period (61 ± 75 versus 108 ± 49 g, p < 0.0001). After adjusting for female sex, hypertension, and baseline LV mass, high PTH values were found to be independent predictor of less LV mass regression at 2-year follow-up (β = 0.23, r2 = 0.24, p = 0.02). In conclusion, the HD patients with high levels of PTH presented with less LV mass regression after AVR for AS without patient-prosthesis mismatch. Secondary hyperparathyroidism may impair regression of cardiac hypertrophy after AVR in HD patients with AS.

Для цитирования: Takami Yoshiyuki, Tajima Kazuyoshi. Impact of secondary hyperparathyroidism on ventricular mass regression after aortic valve replacement for aortic stenosis in hemodialysis-dependent patients.. Heart and vessels. 2014. DOI: 10.1007/s00380-014-0512-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.