Ex vivo magnetic resonance elastography of the small bowel in Crohn's disease.

Loch Florian N, Kamphues Carsten, Beyer Katharina, Schineis Christian, Asbach Patrick, Reiter Rolf, Sack Ingolf, Braun Jürgen

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Conventional magnetic resonance enterography is limited in differentiating active inflammation and fibrosis in lesions of Crohn's disease (CD), thus providing a restricted basis for therapeutic decision making. Magnetic resonance elastography (MRE) is an emerging imaging tool that differentiates soft tissues on the basis of their viscoelastic properties. The aim of this study was to demonstrate the feasibility of MRE in assessing the viscoelastic properties of small bowel samples and quantifying differences in viscoelastic properties between healthy ileum and ileum affected by CD.

METHODS

Twelve patients (median age: 48 years) were prospectively enrolled in this study between September 2019 and January 2021. Patients of the study group (n=7) underwent surgery for terminal ileal CD, while patients of the control group (n=5) underwent segmental resection of healthy ileum. MRE of ileal tissue samples of surgical specimens from both groups was performed in a compact tabletop MRI scanner. Penetration rate (a in m/s) and shear wave speed (c in m/s) were determined as markers of viscosity and stiffness for vibration frequencies f of 1,000, 1,500, 2,000, 2,500, and 3,000 Hz. Additionally, damping ratio γ was deduced, and frequency-independent viscoelastic parameters were calculated using the viscoelastic spring-pot model.

RESULTS

Penetration rate a was significantly lower in CD-affected ileum compared to healthy ileum for all vibration frequencies (P<0.05). Consistently, damping ratio γ was higher in CD-affected ileum, averaged over all frequencies (healthy: 0.58±0.12, CD: 1.04±0.55, P=0.03), as well as at 1,000 and 1,500 Hz individually (P<0.05). Spring-pot-derived viscosity parameter η was also significantly reduced in CD-affected tissue (2.62±1.37 versus 10.60±12.60 Pa·s, P=0.02). No significant difference was found for shear wave speed c between healthy and diseased tissue at any frequency (P>0.05).

CONCLUSIONS

MRE of surgical small bowel specimens is feasible, allowing determination of viscoelastic properties and reliable quantification of differences in viscoelastic properties between healthy and CD-affected ileum. Thus, the results presented here are an important prerequisite for future studies investigating comprehensive MRE mapping and exact histopathological correlation including characterization and quantification of inflammation and fibrosis in CD.

Для цитирования: Loch Florian N, Kamphues Carsten, Beyer Katharina, Schineis Christian, Asbach Patrick, Reiter Rolf, Sack Ingolf, Braun Jürgen. Ex vivo magnetic resonance elastography of the small bowel in Crohn's disease.. Quantitative imaging in medicine and surgery. 2023. DOI: 10.21037/qims-22-1071.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.