MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3791/72212

Медицинская библиотека · Journal of visualized experiments : JoVE · 2026

Redox-Responsive Surface-Enhanced Raman Scattering Microneedles for Monitoring Acupuncture Responses in Rats With Impaired Glucose Tolerance.

Wang Jiajia, Zhang Yuyao, Wang Yang, Dong Jian, Ai Bingwei

СтатьяVideo-Audio MediaПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Impaired glucose tolerance (IGT) is associated with disturbed redox homeostasis and increased oxidative stress, but dynamic in vivo tracking of redox-associated changes during acupuncture intervention remains technically challenging. This study developed a redox-sensitive surface-enhanced Raman scattering (SERS)-active microneedle system for simultaneous acupuncture intervention and relative ratiometric tracking of oxidative capacity (OC)- and redox potential (RP)-related SERS indices in rats with IGT. Oxidative- and redox-sensitive SERS probes were prepared by functionalizing gold nanoshells (GNS) with p-phenylenediamine (p-PDA) for OC responsiveness and anthraquinone for RP responsiveness, respectively. The probes were loaded into two etched grooves on acupuncture needles to construct SERS-active microneedles. Specific-pathogen-free male Sprague-Dawley rats were used in this exploratory study. Three rats served as normal controls, and 20 rats were fed a high-fat diet and administered streptozotocin (STZ) to induce IGT. After screening, 18 eligible IGT rats were divided into high-fat-diet and normal-diet groups, with 9 rats per diet group. Each diet group was further divided into acupuncture-point twisting, non-acupuncture-site twisting, and acupuncture-point direct-insertion subgroups, with 3 rats per subgroup. Needling was performed twice daily for 7 consecutive days, and fasting blood glucose (FPG), 2 h postprandial blood glucose (2hPG), and OC- and RP-related SERS indices were recorded. The results showed that needling at acupuncture points with twisting was associated with lower FPG and 2hPG values and altered OC- and RP-related SERS indices in this IGT rat model. Because external calibration curves, independent biochemical oxidative-stress assays, probe-leaching tests, and biocompatibility assays were not included, the SERS ratios should be interpreted as relative redox-associated optical indices rather than absolute biochemical concentrations or absolute redox-potential values. These findings support the feasibility of SERS-active microneedles as an exploratory preclinical platform for combining acupuncture intervention with local ratiometric SERS tracking in IGT rats.

Для цитирования: Wang Jiajia, Zhang Yuyao, Wang Yang, Dong Jian, Ai Bingwei. Redox-Responsive Surface-Enhanced Raman Scattering Microneedles for Monitoring Acupuncture Responses in Rats With Impaired Glucose Tolerance.. Journal of visualized experiments : JoVE. 2026. DOI: 10.3791/72212.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.