MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/(sici)1522-2586(199903)9:3<378::aid-jmri3>3.0.co;2-9

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 1999

Pelvic floor descent: dynamic MR imaging using a half-Fourier RARE sequence.

Gufler H, Laubenberger J, DeGregorio G, Dohnicht S, Langer M

Клиническое исследованиеСравнительное исследованиеКонтролируемое клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

Dynamic magnetic resonance imaging (MRI) using a single shot fast spin-echo technique was evaluated as a noninvasive alternative to cystourethography or colpocystorectography in patients with pelvic organ prolapse and/or urinary incontinence. Thirty-two patients were included in this prospective study. Colpocystorectography was performed in 10 patients who previously had undergone hysterectomy and in 2 patients without history of hysterectomy with clinical suspicion of rectoceles. Bead-chain cystourethrography was performed in 20 patients without hysterectomy. For dynamic MRI, a single-slice half-Fourier RARE sequence (imaging time 2 seconds) was used to depict the pelvic organs at different levels of pelvic strain. The results obtained with dynamic MRI were correlated with the x-ray findings. All 17 cystoceles, 10 rectoceles, 2 enteroceles, and 7 vaginal prolapses could be demonstrated on MRI. Diagnostic information gained from these images was equivalent to that obtained with colpocystorectography and superior to that obtained with cystourethrography; with the latter, important findings were missed (four rectoceles). We conclude that dynamic MRI of the pelvic floor with a half-Fourier RARE sequence can reliably detect descents of all three pelvic compartments, that it requires no contrast agent, and that no radiation exposure is involved.

Для цитирования: Gufler H, Laubenberger J, DeGregorio G, Dohnicht S, Langer M. Pelvic floor descent: dynamic MR imaging using a half-Fourier RARE sequence.. Journal of magnetic resonance imaging : JMRI. 1999. DOI: 10.1002/(sici)1522-2586(199903)9:3<378::aid-jmri3>3.0.co;2-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.