MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000001403

Медицинская библиотека · Nuclear medicine communications · 2021

Dual-tracer approach vs. dual time-point approach in leukocyte scintigraphy in treatment evaluation of persistent chronic prosthetic joint infection.

Teiler Johan, Åkerlund Börje, Brismar Harald, Savitcheva Irina, Ahl Marcus, Bjäreback Annie, Hedlund Håkan, Holstensson Maria, Axelsson Rimma

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Both dual time-point 99mTc-hexamethylpropylene amine oxime (HMPAO)-leukocyte scintigraphy and dual-tracer 99mTc-HMPAO-leukocyte scintigraphy (with the addition of 99mTc-nanocolloid bone marrow scintigraphy) have been used to diagnose prosthetic joint infection (PJI). A treatment evaluation of persistent PJI using these imaging protocols has yet to be presented.

OBJECTIVE

The purpose of this study was to compare the accuracy of dual time-point 99mTc-HMPAO-leukocyte scintigraphy to the dual-tracer alternative of single time-point 99mTc-HMPAO-leukocyte scintigraphy or single-photon emission computed tomography/computed tomography (SPECT/CT) combined with a 99mTc-nanocolloid bone marrow scintigraphy or SPECT/CT, for treatment evaluation of PJI.

MATERIAL AND

METHODS

Thirty-one PJI patients under antibiotic treatment were included in this retrospective study. Examinations were organized into three settings. Setting one used dual time-point approach with delayed (2 h) and late (24 h) planar 99mTc-HMPAO-leukocyte scintigraphy, including both visual and semiquantitative analysis. Setting two used delayed (2 h) planar 99mTc-HMPAO-leukocyte scintigraphy combined with 99mTc-nanocolloid bone marrow scintigraphy and for setting three SPECT/CT replaced planar imaging.

RESULTS

Accuracy was 0.68 for visual evaluation and 0.55 for semiquantitative evaluation of setting one; 0.71 for setting two; and 0.68 for setting three. Sensitivity was 0.54 for visual evaluation and 0.31 for semiquantitative evaluation of setting one; 0.38 for setting two; and 0.46 for setting three. Specificity was 0.78 for visual evaluation and 0.72 for semiquantitative evaluation of setting one; 0.94 for setting two; and 0.83 for setting three.

CONCLUSION

No significant difference in accuracy, sensitivity, or specificity between the approaches for treatment evaluation of suspected persistent PJI in the hip or knee was observed.

Для цитирования: Teiler Johan, Åkerlund Börje, Brismar Harald, Savitcheva Irina, Ahl Marcus, Bjäreback Annie, Hedlund Håkan, Holstensson Maria, Axelsson Rimma. Dual-tracer approach vs. dual time-point approach in leukocyte scintigraphy in treatment evaluation of persistent chronic prosthetic joint infection.. Nuclear medicine communications. 2021. DOI: 10.1097/mnm.0000000000001403.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.