MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics11020242

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2021

Endoscopic Ultrasound Quality Metrics in Clinical Practice.

Ku Lawrence, Hou Linda A, Eysselein Viktor E, Reicher Sofiya

СтатьяПеревод пока не подготовлен

Аннотация

Recent advances in endoscopic ultrasound (EUS), particularly EUS-guided tissue acquisition, may have affected EUS procedural performance as measured by current American Society for Gastrointestinal Endoscopy (ASGE)/American College of Gastroenterology (ACG) quality indicators. Our study aims to assess how these quality metrics are met in clinical practice. We retrospectively analyzed 732 EUS procedures; data collected were procedural indications, technical aspects and outcomes, completeness of documentation, and malignancy staging. EUS was performed in 660 patients for a variety of indications. All ASGE/ACG EUS procedural quality metrics were met or exceeded. Intervention was successful in 97.7% (715/732) of cases, with complication rate of 0.4% (3/732). EUS outcomes changed clinical management in 58.7% of all cases and in 91.2% of malignancy work-up cases; in 26.0% of suspected choledocholithiasis cases, endoscopic retrograde cholangiopancreatography (ERCP) was avoided after EUS. Locoregional EUS staging was accurate in 61/65 (93.8%) cases of non-metastatic disease and in 15/22 (68.2%) cases of metastatic disease. Pancreatic mass malignancy detection rate with EUS-guided fine needle aspiration (FNA) or fine needle biopsy (FNB) was 75.8%, with a sensitivity of 96.2%; a significant increase in detection rate from 46.2% (6/13) to 95.0% (19/20) (p = 0.0026) was observed with a transition to the predominant use of FNB for tissue acquisition. All ASGE/ACG EUS quality metrics were met or exceeded for EUS procedures performed for a wide variety of indications in a diverse patient population. EUS was instrumental in changing clinical management, with a low complication rate. The malignancy detection rate in pancreatic masses significantly increased with FNB use.

Для цитирования: Ku Lawrence, Hou Linda A, Eysselein Viktor E, Reicher Sofiya. Endoscopic Ultrasound Quality Metrics in Clinical Practice.. Diagnostics (Basel, Switzerland). 2021. DOI: 10.3390/diagnostics11020242.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.