MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12350-022-03133-y

Медицинская библиотека · Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022

99mTc-PYP SPECT and SPECT/CT quantitation for diagnosing cardiac transthyretin amyloidosis.

Nichols Kenneth J, Yoon Se-Young, Van Tosh Andrew, Palestro Christopher J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We investigated quantitative 99mTc-pyrophosphate (PYP) SPECT/CT reproducibility and accuracy for diagnosing cardiac transthyretin amyloidosis (ATTR), and whether SPECT/CT improved visual and quantitative results compared to SPECT-only.

METHODS

Data were reviewed for 318 patients with suspected ATTR who underwent PYP SPECT/CT. Myocardial-to-blood pool count (MBP) ratios were computed and repeated independently > 1 month later. A physician independently scored LV myocardial-to-rib uptake on SPECT/CT as: 0 (negative), 1 < rib (equivocal), 2 = rib (positive) or 3 > rib (positive), and the image quality as: 1 (poor), 2 (adequate), and 3 (good). SPECT-only MBP ratios and visual scores were assessed separately for a subgroup of the first sequential 191 patients.

RESULTS

25% of patients had positive myocardial uptake (myocardial-to-rib uptake score of ≥ 2). SPECT/CT MBP ratios were reproducible (1.35 ± .68 vs 1.33 ± .74, p = .09) and corresponded with visual scores ≥ 2 (ROC AUC = 99 ± 1%) more accurately than SPECT-only MBPs (93 ± 3%, p = .02). SPECT/CT image quality was better than that of SPECT-only (2.7 ± .5 vs 2.1 ± .5, p < .0001) with fewer equivocal results (2.6% vs 22.5%, p < .0001).

CONCLUSION

SPECT/CT produces MBP ratios that are reproducible and accurately identify a positive scan, with better image quality and fewer equivocal cases than SPECT-only.

Для цитирования: Nichols Kenneth J, Yoon Se-Young, Van Tosh Andrew, Palestro Christopher J. 99mTc-PYP SPECT and SPECT/CT quantitation for diagnosing cardiac transthyretin amyloidosis.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2022. DOI: 10.1007/s12350-022-03133-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.