MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0271572

Медицинская библиотека · PloS one · 2023

Diagnostic accuracy of magnetic resonance elastography and point-shear wave elastography for significant hepatic fibrosis screening: Systematic review and meta-analysis.

Schambeck João Paulo L, Forte Gabriele C, Gonçalves Luana M, Stuker Guilherme, Kotlinski João Bruno F, Tramontin Giacomo, Altmayer Stephan, Watte Guilherme, Hochhegger Bruno

МетаанализСистематический обзорСтатьяПеревод пока не подготовлен

Аннотация

The hepatic diseases are extremely common in clinical practice. The correct classification of liver fibrosis is extremely important, as it influences therapy and predicts disease outcomes. The purpose of this study is to compare the diagnostic performance of point-shear wave elastography (pSWE) and magnetic resonance elastography (MRE) in the hepatic fibrosis diagnostic. A meta-analysis was carried out based on articles published until October 2020. The articles are available at following databases: MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, Scientific Electronic Library Online, LILACS, Scopus, and CINAHL. Diagnostic performances were analyzed per METAVIR F2, using 3.5kPa as target fibrosis. Assessment of the methodological quality of the incorporated papers by the QUADAS-2 tool for pSWE and MRE. A total 2,153 studies articles were evaluated and 44 studies, comprising 6,081 patients with individual data, were included in the meta-analysis: 28 studies for pSWE and 16 studies for MRE. The pooled sensitivity and specificity were 0.86 (95%CI 0.80-0.90) and 0.88 (95%CI 0.85-0.91), respectively, for pSWE, compared with 0.94 (95%CI 0.89-0.97) and 0.95 (95%CI 0.89-0.98) respectively, for MRE. The pooled SROC curve for pSWE shows in the area under the curve (AUC) of 0.93 (95%CI 0.90-0.95), whereas the AUC for MRE was 0.98 (95%CI 0.96-0.99). The diagnostic odds ratio for pSWE and MRE were 41 (95%CI 24-72) and 293 (95%CI 86-1000), respectively. There was statistically significant heterogeneity for pSWE sensitivity (I² = 85.26, P<0.001) and specificity (I² = 89.46, P<0.001). The heterogeneity for MRE also was significant for sensitivity (I² = 73.28, P<0.001) and specificity (I² = 87.24, P<0.001). Therefore, both pSWE and MRE are suitable modalities for assessing liver fibrosis. In addition, MRE is a more accurate imaging technique than pSWE and can be used as alternative to invasive biopsy.

Для цитирования: Schambeck João Paulo L, Forte Gabriele C, Gonçalves Luana M, Stuker Guilherme, Kotlinski João Bruno F, Tramontin Giacomo, Altmayer Stephan, Watte Guilherme, Hochhegger Bruno. Diagnostic accuracy of magnetic resonance elastography and point-shear wave elastography for significant hepatic fibrosis screening: Systematic review and meta-analysis.. PloS one. 2023. DOI: 10.1371/journal.pone.0271572.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.