MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0030-1250499

Медицинская библиотека · The Thoracic and cardiovascular surgeon · 2011

Biological materials for diaphragmatic repair: initial experiences with the PeriGuard Repair Patch®.

Zardo P, Zhang R, Wiegmann B, Haverich A, Fischer S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We sought to analyze the efficacy of a bovine pericardial patch (PeriGuard®) for diaphragmatic repair.

METHODS

Seven consecutive patients (6 males, median age 56 years) scheduled for diaphragmatic resection and/or repair were enrolled in this study. In all cases diaphragmatic repair was performed with a PeriGuard Repair Patch® (Synovis, St. Paul, MN, USA). At follow-up (median: 12 months; range: 6-18 months), quality of life, signs of reherniation and incorporation of mesh were assessed through clinical examination, blood samples and CT or MRT scan.

RESULTS

Diagnosis on admission included sarcoma (n = 2), mesothelioma (n = 1), squamous cell carcinoma (n = 1), parachordoma (n = 1) and large congenital or posttraumatic herniation (n = 2). At follow-up successful diaphragmatic repair with no signs of reherniation, graft dehiscence or seroma formation was confirmed for all patients. Recorded inflammatory markers [C-reactive protein (CRP), white blood cell count (WBC) and procalcitonin (PCT)] reached their peak values between postoperative day (POD) 4 and POD 7. Values ranged from 122-282 mg/L for CRP, 0.4-4.6 µg/L for PCT and 6.2-15.6 Tsd/µL for WBC. Overall oncological results were good and 5 out of 6 survivors reported a fully reestablished quality of life.

CONCLUSION

We consider the PeriGuard Repair Patch® a viable alternative to synthetic materials for diaphragm replacement. Moreover, we advise carrying out cautious follow-up in patients undergoing extensive oncological resection to learn more about the biological behavior of the bovine PeriGuard Repair Patch® after diaphragmatic repair.

Для цитирования: Zardo P, Zhang R, Wiegmann B, Haverich A, Fischer S. Biological materials for diaphragmatic repair: initial experiences with the PeriGuard Repair Patch®.. The Thoracic and cardiovascular surgeon. 2011. DOI: 10.1055/s-0030-1250499.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.