Novel Image-Guided Simulator for Transcervical Intralaryngeal Injection Training.

Kaiser Zane, Zeatoun Abdullah, Shah Rupali N, Buckmire Robert A

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE(S): To assess the impact of a novel 3D-printed simulation model with Brainlab Image Guidance on enhancing otolaryngology residents' skills and confidence in performing transcervical intralaryngeal injection (TII) compared with conventional training methods.

METHODS

Utilizing a 3D-printed larynx model derived from computed tomography (CT) scans, this study involved 16 otolaryngology residents divided into two groups for TII training: one with Brainlab Image Guidance (LMIG) and the other without (LM). Pre- and post-training evaluations measured participants' confidence while the Brainlab system measured the accuracy of their needle placements.

RESULTS

After training, participants exhibited a significant increase in confidence with an average rise from 1.56 to 2.75 on a 5-point scale. The LMIG group outperformed the LM group in accuracy achieving statistically significant reductions in target distances after training (3.5 mm right, 3.6 mm left). The LMIG also demonstrated a significantly greater increase in procedural confidence over the LM group after training.

CONCLUSION

The TII laryngeal model with Brainlab Image Guidance significantly improves procedural confidence and accuracy among otolaryngology residents, signifying potential advantage over a more conventional training approach. The model's realistic tactile and live instrument positioning feedback augments the process of surgical skill refinement in a controlled, risk-free, simulation environment.

LEVEL OF EVIDENCE: NA Laryngoscope, 135:763-768, 2025.

Для цитирования: Kaiser Zane, Zeatoun Abdullah, Shah Rupali N, Buckmire Robert A. Novel Image-Guided Simulator for Transcervical Intralaryngeal Injection Training.. The Laryngoscope. 2024. DOI: 10.1002/lary.31835.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.