MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3748/wjg.15.2245

Медицинская библиотека · World journal of gastroenterology · 2009

Contrast-enhanced sonography versus biopsy for the differential diagnosis of thrombosis in hepatocellular carcinoma patients.

Sorrentino Paolo, D'Angelo Salvatore, Tarantino Luciano, Ferbo Umberto, Bracigliano Alessandra, Vecchione Raffaela

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIM: To clarify which method has accuracy: 2nd generation contrast-enhanced ultrasound or biopsy of portal vein thrombus in the differential diagnosis of portal vein thrombosis.

METHODS

One hundred and eighty-six patients with hepatocellular carcinoma and portal vein thrombosis underwent in blinded fashion a 2nd generation contrast-enhanced ultrasound and biopsy of portal vein thrombus; both results were examined on the basis of the follow-up of patients compared to reference-standard.

RESULTS

One hundred and eight patients completed the study. Benign thrombosis on 2nd generation contrast-enhanced ultrasound was characterised by progressive hypoenhancing of the thrombus; in malignant portal vein thrombosis there was a precocious homogeneous enhancement of the thrombus. On follow-up there were 50 of 108 patients with benign thrombosis: all were correctly diagnosed by both methods. There were 58 of 108 patients with malignant thrombosis: amongst these, 52 were correctly diagnosed by both methods, the remainder did not present malignant cells on portal vein thrombus biopsy and showed on 2nd generation contrast-enhanced ultrasound an inhomogeneous enhancement pattern. A new biopsy during the follow-up, guided to the area of thrombus that showed up on 2nd generation contrast-enhanced ultrasound, demonstrated an enhancing pattern indicating malignant cells.

CONCLUSION

In patients with hepatocellular carcinoma complicated by portal vein thrombosis, 2nd generation contrast-enhanced ultrasound of portal vein thrombus is very useful in assessing the benign or malignant nature of the thrombus. Puncture biopsy of thrombus is usually accurate but presents some sampling errors, so, when pathological results are required, 2nd generation contrast-enhanced ultrasound could guide the sampling needle to the correct area of the thrombus.

Для цитирования: Sorrentino Paolo, D'Angelo Salvatore, Tarantino Luciano, Ferbo Umberto, Bracigliano Alessandra, Vecchione Raffaela. Contrast-enhanced sonography versus biopsy for the differential diagnosis of thrombosis in hepatocellular carcinoma patients.. World journal of gastroenterology. 2009. DOI: 10.3748/wjg.15.2245.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.