m+Medelevator.RU
← Поиск публикаций
Burns : journal of the International Society for Burn Injuries · 2024

Bacterial fluorescence imaging as a predictor of skin graft integration in burn wounds.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hanson-Viana Erik, Rojas-Ortiz Jorge Arturo, Rendón-Medina Marco Aurelio, Luna-Zepeda Brenda Lorena

Аннотация

BACKGROUND: Split-thickness skin graft (STSG)1 integration rates are susceptible to improvement. Infection and/or biofilm should be appropriately addressed prior to grafting to improve the likelihood of graft-take. Incorporating technological aids such as fluorescence (FL)2 imaging (MolecuLight®), which accurately locates areas of bacterial loads above 104 CFU/gr, for graft site assessment and preparation could yield better outcomes.

METHODS: This single-center, prospective observational study included adult burn patients with previously infected wounds that had been deemed clinically and microbiologically clean and were therefore candidates for grafting. Prior to grafting, a FL imaging assessment (blinded to the surgical team) localized areas positive for moderate-high bacterial loads (>104 CFU/gr). Intra-operatively, a standard swab sample from the recipient site was collected by the surgical team. Postoperatively, areas positive/negative for FL and areas of graft take and failure were overlapped and measured (cm2) over a 2D schematic. The performance and accuracy of FL imaging and swab sampling in relation to graft outcomes were assessed.

RESULTS: 38 patients were enrolled in the study. The mean total body surface area (TBSA)3 involvement was 14.5 ± 12.4 % [range 0.8 - 40.2 %]. 25/38 of the subjects enrolled had complete graft take while 13 had partial graft losses. There were no total losses. FL-imaging was positive in 100 % of losses versus 31 % (4/13) of the swab microbiology. FL-imaging was found to have a sensitivity of 86 %, specificity of 98 %, PPV of 72 %, NPV of 99 %, and an accuracy of 94 % for predicting any type or range of graft loss in the entire cohort. Meanwhile, the sensitivity of microbiology from swab samples was 30 %, with a specificity of 76 %.

CONCLUSIONS: FL imaging is an accurate method for assessing recipient sites and predicting the outcome of a skin graft among burn patients. These findings suggest that FL imaging can inform better decision-making surrounding grafts that may lead to better outcomes.

LEVEL OF EVIDENCE: Level IIA, Therapeutic study.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты