MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1524-4725.2012.02375.x

Медицинская библиотека · Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.] · 2012

Clinical evaluation of a microwave device for treating axillary hyperhidrosis.

Hong H Chih-ho, Lupin Mark, O'Shaughnessy Kathryn F

Оценочное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

A third-generation microwave-based device has been developed to treat axillary hyperhidrosis by selectively heating the interface between the skin and underlying fat where the sweat glands reside.

MATERIALS AND

METHODS

Thirty-one (31) adults with primary axillary hyperhidrosis were enrolled. All subjects had one to three procedure sessions over a 6-month period to treat both axillae fully. Efficacy was assessed using the Hyperhidrosis Disease Severity Scale (HDSS), gravimetric weight of sweat, and the Dermatologic Life Quality Index (DLQI), a dermatology-specific quality-of-life scale. Subject safety was assessed at each visit. Subjects were followed for 12 months after all procedure sessions were complete.

RESULTS

At the 12-month follow-up visit, 90.3% had HDSS scores of 1 or 2, 90.3% had at least a 50% reduction in axillary sweat from baseline, and 85.2% had a reduction of at least 5 points on the DLQI. All subjects experienced transient effects in the treatment area such as swelling, discomfort, and numbness. The most common adverse event (12 subjects) was the presence of altered sensation in the skin of the arm that resolved in all subjects.

CONCLUSION

The device tested provided efficacious and durable treatment for axillary hyperhidrosis.

Для цитирования: Hong H Chih-ho, Lupin Mark, O'Shaughnessy Kathryn F. Clinical evaluation of a microwave device for treating axillary hyperhidrosis.. Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.]. 2012. DOI: 10.1111/j.1524-4725.2012.02375.x.