m+Medelevator.RU
← Поиск публикаций
Stroke and vascular neurology · 2024

Assessment of Perfusion Volumes by a New Automated Software for Computed Tomography Perfusion.

СтатьяМногоцентровое исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cao Zhixin, Wang David, Feng Xueyan, Yang Pengfei, Wang Hao, Xu Ziqi, Hao Yahui, Ye Wanxing, Chen Fengwei, Wang Liyuan, Hao Manjun, Wu Na, Yang Kai-Xuan, Xiong Yunyun, Wang Yongjun

Аннотация

INTRODUCTION: To compare the perfusion volumes assessed by a new automated CT perfusion (CTP) software iStroke with the circular singular value decomposition software RAPID and determine its predictive value for functional outcome in patients with acute ischaemic stroke (AIS) who underwent endovascular treatment (EVT).

METHODS: Data on patients with AIS were collected from four hospitals in China. All patients received CTP followed by EVT with complete recanalisation within 24 hours of symptom onset. We evaluated the agreement of CTP measures between the two softwares by Spearman's rank correlation tests and kappa tests. Bland-Altman plots were used to evaluate the agreement of infarct core volume (ICV) on CTP and ground truth on diffusion-weighted imaging (DWI). Logistic regression models were used to test the association between ICV on these two softwares and functional outcomes.

RESULTS: Among 326 patients, 228 had DWI examinations and 40 of them had infarct volume >70 mL. In all patients, the infarct core and hypoperfusion volumes on iStroke had a strong correlation with those on RAPID (ρ=0.68 and 0.66, respectively). The agreement of large infarct core (volume >70 mL) was substantial (kappa=0.73, p<0.001) between these two softwares. The ICV measured by iStroke and RAPID was significantly correlated with independent functional outcome at 90 days (p=0.009 and p<0.001, respectively). In patients with DWI examinations and those with an ICV >70 mL, the ICV of iStroke and RAPID was comparable on individual agreement with ground truth.

CONCLUSION: The automatic CTP software iStroke is a reliable tool for assessing infarct core and mismatch volumes, making it clinically useful for selecting patients with AIS for acute reperfusion therapy in the extended time window.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты