OBJECTIVE

The objective was to investigate the effect of extracorporeal shock wave therapy (ESWT) on the magnitude of orthodontic tooth movement, in a rat model, based on a previously established treatment protocol.

DESIGN

In conjunction with orthodontic force commencement, rats underwent ESWT. The amount of tooth movement along with different microarchitectural parameters were measured after three weeks by means of microcomputed tomography. In addition, the percentage of cells expressing vascular endothelial growth factor, the number of tartrate-resistant acid phosphatase (TRAP) positive cells/area and blood vessel density were evaluated both for the pressure and tension sides.

RESULTS

The addition of ESWT to the orthodontic force after three weeks more than doubled the average tooth movement. The addition of ESWT on the pressure side induced a significant decrease in volumetric bone mineral density. Blood vessel density and the number of TRAP positive cells were higher after the application of ESWT.

CONCLUSION

The induction of ESWT during orthodontic tooth movement in a rat model increases the rate of tooth movement by accelerating bone resorption on the pressure side and possibly enhances bone formation on the tension side.

Для цитирования: Hazan-Molina Hagai, Gabet Yankel, Aizenbud Itay, Aizenbud Nitzan, Aizenbud Dror. Orthodontic force and extracorporeal shock wave therapy: Assessment of orthodontic tooth movement and bone morphometry in a rat model.. Archives of oral biology. 2021. DOI: 10.1016/j.archoralbio.2021.105327.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.