MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jos.jos_17_20

Медицинская библиотека · Journal of orthodontic science · 2021

Comparison of two different initial archwires for tooth alignment during fixed orthodontic treatment-A randomized clinical trial.

Jain Shubhangi, Sharma Payal, Shetty Divya

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of the study was to clinically evaluate and compare 0.016-inch superelastic nickel-titanium (NiTi) and 0.016-inch heat-activated nickel-titanium (NiTi) archwires in terms of alignment efficiency, root resorption, and pain intensity.

METHOD: A total of 20 patients requiring fixed orthodontic treatment, having Little's irregularity index of 5-8, and requiring first premolar extractions were recruited. They were randomly allocated to receive two different archwires (0.016-inch superelastic NiTi or 0.016-inch thermoelastic NiTi). Good-quality impressions were taken of the lower arch before archwire placement (T0) and at every month after that till the alignment was complete. The rate of tooth alignment was measured on casts by determining Little's irregularity index. The pain experienced by the patient was assessed 24 hours and 1 week after the placement of the archwire on a visual analogue scale. Cone beam computed tomographic radiographs of lower anterior teeth were taken before and after alignment to assess root resorption. Data obtained were subjected to statistical analysis using the SPSS software (version 20.0). The level of significance was kept at 5%.

RESULTS

The repeated measures ANOVA indicated that there was no significant difference in the aligning efficiency of superelastic and heat-activated NiTi wires. (p = 0.45). The Mann Whitney U test showed that superelastic NiTi wires had statistically significant higher VAS scores than heat-activated NiTi at 24 hours and 1-week interval (p < 0.05). Student's t-test indicated greater root resorption with superelastic NiTi but the difference was not statistically significant.

CONCLUSION

Both the wires showed similar aligning efficiency and resulting root resorption. Superelastic NiTi was observed to produce more pain compared to heat-activated NiTi in the aligning phase.

Для цитирования: Jain Shubhangi, Sharma Payal, Shetty Divya. Comparison of two different initial archwires for tooth alignment during fixed orthodontic treatment-A randomized clinical trial.. Journal of orthodontic science. 2021. DOI: 10.4103/jos.jos_17_20.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.