MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.12442

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2014

Renal dysfunction and clinical outcomes of patients undergoing ICD and CRTD implantation: data from the Israeli ICD registry.

Eisen Alon, Suleiman Mahmoud, Strasberg Boris, Sela Ron, Rosenheck Shimon, Freedberg Nahum A, Geist Michael, Ben-Zvi Shlomit, Goldenberg Ilan, Glikson Michael, Haim Moti, Israeli working group of pacing and electrophysiology of the Israel Heart Society

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy (CRT) reduce mortality in patients with heart failure (HF) and left ventricular dysfunction. However, their efficacy in patients with chronic kidney disease (CKD) is controversial.

OBJECTIVE

We examined the association between renal dysfunction and clinical outcomes in patients undergoing ICD and CRT defibrillator (CRTD) implantation.

METHODS

Data were collected from the Israeli ICD registry. Estimated glomerular filtration rate (eGFR) at implantation was assessed using the modification of diet in renal disease formula. Primary outcome was all-cause mortality. Secondary outcomes included the composite endpoints of death or HF and death or ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation [VT/VF]); any hospitalizations; first appropriate and inappropriate ICD therapy.

RESULTS

During the study period (July 2010-November 2012), 2,811 patients were implanted with ICD or CRTD. One-year follow-up data were available for 730 ICD patients and 453 CRTD patients. Patients with eGFR < 30 mL/minute/1.73 m(2) (n = 54, 4.6%) were older, had a higher prevalence of diabetes, hypertension, or ischemic heart disease. eGFR <30 mL/minute/1.73 m(2) was associated with increased mortality risk in ICD (HR 5.4; 95% CI 1.5-19.2), but not in CRTD patients (HR 0.9; 95% CI 0.1-7.5). Renal dysfunction was associated with the composite endpoints of death or HF and death or VT/VF in ICD, but not in CRTD patients. Mean eGFR during follow-up decreased by 8.0 ± 4.3 mL/minute/1.73 m(2) in ICD patients (P = 0.06) and by 1.8 ± 1.3 mL/minute/1.73 m(2) in patients with CRTD (P = 0.2).

CONCLUSION

Based on this retrospective analysis, CKD is associated with adverse prognosis after ICD implantation, but not after CRTD implantation. GFR decreased in patients with ICD, but not in CRTD patients.

Для цитирования: Eisen Alon, Suleiman Mahmoud, Strasberg Boris, Sela Ron, Rosenheck Shimon, Freedberg Nahum A, Geist Michael, Ben-Zvi Shlomit, Goldenberg Ilan, Glikson Michael, Haim Moti, Israeli working group of pacing and electrophysiology of the Israel Heart Society. Renal dysfunction and clinical outcomes of patients undergoing ICD and CRTD implantation: data from the Israeli ICD registry.. Journal of cardiovascular electrophysiology. 2014. DOI: 10.1111/jce.12442.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.