MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.13875

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2019

Low lead one ratio predicts clinical outcomes in left bundle branch block.

Loring Zak, Atwater Brett D, Xia Xiaojuan, Axelsson Jimmy, Klem Igor, Nijveldt Robin, Schelbert Erik B, Couderc Jean-Philippe, Strauss David G, Ugander Martin, Wieslander Björn

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

We evaluated the association between a novel electrocardiographic (ECG) marker of late, rightward electrocardiographic forces (termed the lead one ratio [LOR]), and left ventricular ejection fraction (LVEF), myocardial scar, and clinical outcomes in patients with left bundle branch block (LBBB).

METHODS AND

RESULTS

LOR was calculated in patients with LBBB from a derivation cohort (n = 240) and receiver operator characteristic curves identified optimal threshold values for predicting myocardial scar and LVEF less than 35%. An independent validation cohort of patients with LBBB (n = 196) was used to test the association of LOR with the myocardial scar, LVEF, and the likelihood of death, heart transplant or left ventricular assist device (LVAD) implantation. The optimal thresholds in the derivation cohort were LOR less than 13.7 for identification of scar (sensitivity 55%, specificity 80%), and LOR less than 12.1 for LVEF less than 35% (sensitivity 49%, specificity 80%). In the validation cohort, LOR less than 13.7 was not associated with scar size or presence (P > 0.05 for both). LOR less than 12.1 was associated with lower LVEF (30 [20-40] versus 40 [25-55]%; P = 0.002) and predicted LVEF less than 35% in univariable (odds ratio [OR], 2.2 [1.2-4.1]; P = 0.01) and multivariable analysis (OR, 2.2 [1.2-4.3]; P = 0.02). LOR less than 12.1 was associated with scar presence when patients with nonischemic cardiomyopathy were excluded (OR = 7.2 [1.5-33.2]; P = 0.002). LOR less than 12.1 had an adjusted hazard ratio of 1.53 ([1.05-2.21]; P = 0.03) for death, transplant or LVAD implantation.

CONCLUSIONS

In conclusion, ECG LOR less than 12.1 predicts reduced-LV systolic function and poorer prognosis in patients with LBBB.

Для цитирования: Loring Zak, Atwater Brett D, Xia Xiaojuan, Axelsson Jimmy, Klem Igor, Nijveldt Robin, Schelbert Erik B, Couderc Jean-Philippe, Strauss David G, Ugander Martin, Wieslander Björn. Low lead one ratio predicts clinical outcomes in left bundle branch block.. Journal of cardiovascular electrophysiology. 2019. DOI: 10.1111/jce.13875.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.