Domain Generalization Mitigates Scanner-Induced Domain Shift in Medical Imaging.

Pulido-Arias Dagoberto, Cleveland Mason C, Patel Jay, Wang Zhewei, Leng Yu, Goncalves Tiago Filipe, Yao Maggie, Kim Albert E, Regge Daniele, Marias Kostas, Tsiknakis Manolis, Huisman Henkjan, Papanikolaou Nikolaos, ProCAncer-I Consortium, Kalpathy-Cramer Jayashree, Bridge Christopher P

СтатьяПеревод пока не подготовлен

Аннотация

Deep learning models for medical image analysis often fail in clinical deployment due to domain shift from varied acquisition hardware and protocols. We present a comprehensive evaluation of various domain generalization (DG) techniques to mitigate this performance degradation. We evaluate six DG algorithms against a baseline on two distinct tasks using large, multi-institutional datasets: grading prostate cancer aggressiveness from MRI using the ProstateNet dataset and assessing breast density from mammograms using the DMIST dataset, using a leave-one-domain-out protocol. Our results show that DG methods, particularly those that explicitly regularize the learning process, improve out-of-domain generalization, but do not fully close the gap with in-domain performance. On the ProstateNet dataset, the FISH algorithm achieved the highest average out-of-domain AUROC (0.678), a statistically significant improvement over the baseline (0.613). We observed similar trends on the DMIST dataset. These findings underscore the necessity of incorporating DG strategies to develop clinically deployable AI models.

Для цитирования: Pulido-Arias Dagoberto, Cleveland Mason C, Patel Jay, Wang Zhewei, Leng Yu, Goncalves Tiago Filipe, Yao Maggie, Kim Albert E, Regge Daniele, Marias Kostas, Tsiknakis Manolis, Huisman Henkjan, Papanikolaou Nikolaos, ProCAncer-I Consortium, Kalpathy-Cramer Jayashree, Bridge Christopher P. Domain Generalization Mitigates Scanner-Induced Domain Shift in Medical Imaging.. Journal of imaging informatics in medicine. 2026. DOI: 10.1007/s10278-026-02082-z.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.