MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euy233

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2018

A left bundle branch block activation sequence and ventricular pacing influence voltage amplitudes: an in vivo and in silico study.

Nguyên Uyên Châu, Potse Mark, Vernooy Kevin, Mafi-Rad Masih, Heijman Jordi, Caputo Maria Luce, Conte Giulio, Regoli François, Krause Rolf, Moccetti Tiziano, Auricchio Angelo, Prinzen Frits W, Maffessanti Francesco

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: The aim of this study was to investigate the influence of the activation sequence on voltage amplitudes by evaluating regional voltage differences during a left bundle branch block (LBBB) activation sequence vs. a normal synchronous activation sequence and by evaluating pacing-induced voltage differences.

METHODS AND

RESULTS

Twenty-one patients and three computer models without scar were studied. Regional voltage amplitudes were evaluated in nine LBBB patients who underwent endocardial electro-anatomic mapping (EAM). Pacing-induced voltage differences were evaluated in 12 patients who underwent epicardial EAM during intrinsic rhythm and right ventricular (RV) pacing. Three computer models customized for LBBB patients were created. Changes in voltage amplitudes after an LBBB (intrinsic), a normal synchronous, an RV pacing, and a left ventricular pacing activation sequence were assessed in the computer models. Unipolar voltage amplitudes in patients were approximately 4.5 mV (4.4-4.7 mV, ∼33%) lower in the septum when compared with other segments. A normal synchronous activation sequence in the computer models normalized voltage amplitudes in the septum. Pacing-induced differences were larger in electrograms with higher voltage amplitudes during intrinsic rhythm and furthermore larger and more variable at the epicardium [mean absolute difference: 3.6-6.2 mV, 40-53% of intrinsic value; interquartile range (IQR) differences: 53-63% of intrinsic value] compared to the endocardium (mean absolute difference: 3.3-3.8 mV, 28-30% of intrinsic value; IQR differences: 37-40% of intrinsic value).

CONCLUSION

In patients and computer models without scar, lower septal unipolar voltage amplitudes are exclusively associated with an LBBB activation sequence. Pacing substantially affects voltage amplitudes, particularly at the epicardium.

Для цитирования: Nguyên Uyên Châu, Potse Mark, Vernooy Kevin, Mafi-Rad Masih, Heijman Jordi, Caputo Maria Luce, Conte Giulio, Regoli François, Krause Rolf, Moccetti Tiziano, Auricchio Angelo, Prinzen Frits W, Maffessanti Francesco. A left bundle branch block activation sequence and ventricular pacing influence voltage amplitudes: an in vivo and in silico study.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2018. DOI: 10.1093/europace/euy233.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.