MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/cj.a2018.0138

Медицинская библиотека · Cardiology journal · 2018

Influence of QRS duration and axis on response to cardiac resynchronization therapy in chronic heart failure with reduced left ventricular ejection fraction: A single center study including patients with left bundle branch block.

Fabiszak Tomasz, Łach Piotr, Ratajczak Jakub, Koziński Marek, Krupa Wojciech, Kubica Jacek

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of the study was to evaluate QRS duration and axis as predictors of response to cardiac resynchronization therapy (CRT) in order to reduce the proportion of non-responders.

METHODS

Retrospective single-center study including 42 CRT recipients, with left bundle branch block (LBBB), left ventricular ejection fraction (LVEF) < 40%, in New York Heart Association (NYHA) class ≥ II. Response to CRT was declared as NYHA class improvement ≥ 1 (symptomatic) and LVEF improvement by ≥ 10% (echocardiographic) > 6 months post implantation.

RESULTS

Symptomatic responders had longer pre- (172.3 ± 17.9 vs. 159.0 ± 18.3 ms; p = 0.027) and postimplantation (157.2 ± 24.1 vs. 136.7 ± 23.2 ms; p = 0.009) QRS duration. Preimplantation QRS < 150 ms predicted poor response (odds ratio [OR] for response vs. lack of response 0.04; 95% confidence interval [CI] 0.001-0.74). Predictors of symptomatic response included: postimplantation QRS > 160 ms (OR 7.2; 95% CI 1.24-41.94), longer QRS duration before (OR for a 1 ms increase 1.04, 95% CI 1.00-1.08) and post implantation (OR for a 1 ms increase 1.04; 95% CI 1.01-1.07). Area under the curve (AUC) for pre- and postimplantation QRS duration was 0.672 (95% CI 0.51-0.84) and 0.727 (95% CI 0.57-0.89), respectively, with cut-off points of 178.5 ms and 157 ms. For post implantation QRS axis, AUC was 0.689 (95% CI 0.53-0.85), with cut-off points of -60.5° or -38.5°. Preimplantation QRS axis was the only predictor of echocardiographic response (OR 0.98; 95% CI 0.96-1.00), with AUC of 0.693 (95% CI 0.54-0.85) and a threshold of -36°.

CONCLUSIONS

Marked pre- and postimplantation QRS prolongation and preimplantation negative QRS axis deviation are moderate predictors of response to CRT.

Для цитирования: Fabiszak Tomasz, Łach Piotr, Ratajczak Jakub, Koziński Marek, Krupa Wojciech, Kubica Jacek. Influence of QRS duration and axis on response to cardiac resynchronization therapy in chronic heart failure with reduced left ventricular ejection fraction: A single center study including patients with left bundle branch block.. Cardiology journal. 2018. DOI: 10.5603/cj.a2018.0138.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.