Novel approach to discriminate left bundle branch block from nonspecific intraventricular conduction delay using pacing-induced functional left bundle branch block.
Аннотация
PURPOSE: Left bundle branch block (LBBB) has a predictive value for response to cardiac resynchronization therapy as reported by Zareba et al. (Circulation 123(10):1061-1072, 2011). However, based on ECG criteria, the discrimination between complete LBBB and nonspecific intraventricular conduction delay is challenging. We tested the hypothesis that discrimination can be performed using standard electrophysiological catheters and a simple stimulation protocol.
METHODS
Fifty-nine patients were analyzed retrospectively. Patients were divided into groups of narrow QRS (n = 20), wide QRS of right bundle branch block (RBBB) morphology (n = 14), and wide QRS of LBBB morphology (n = 25). Using a diagnostic catheter placed in the coronary sinus, left ventricular activation was assessed during intrinsic conduction as well as during right ventricular (RV) stimulation.
RESULTS
In patients with narrow QRS and RBBB, the Q-LV/QRS ratio was 0.43 ± 0.013 (n = 20) and 0.41 ± 0.026 (n = 14), respectively. In patients with LBBB morphology, the Q-LV/QRS split up into a group of patients with normal (0.43 ± 0.022, n = 7) and a group with delayed left ventricular activation (0.75 ± 0.016, n = 18). By direct comparison of the Q-LV/QRS ratio during intrinsic conduction with the Q-LV/QRS ratio during RV pacing leading to a functional LBBB, a clear distinction between a group of "true LBBB" and another group of "apparent LBBB"/nonspecific intraventricular conduction delay (NICD) could be generated.
CONCLUSIONS
We present a novel and practical method that might facilitate discrimination between patients with apparent LBBB and true LBBB by comparing Q-LV/QRS ratios during intrinsic activation and during RV stimulation. Although this method can already be directly applied, validation by 3D electrical mapping and prospective correlation to cardiac resynchronization therapy (CRT) response will be required for further translation into clinical practice.