MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5935/abc.20180159

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2018

Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect.

Nascimento Erivelton Alessandro do, Reis Christiane Cigagna Wiefels, Ribeiro Fernanda Baptista, Alves Christiane Rodrigues, Silva Eduardo Nani, Ribeiro Mario Luiz, Mesquita Claudio Tinoco

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Heart failure (HF) affects more than 5 million individuals in the United States, with more than 1 million hospital admissions per year. Cardiac resynchronization therapy (CRT) can benefit patients with advanced HF and prolonged QRS. A significant percentage of patients, however, does not respond to CRT. Electrical dyssynchrony isolated might not be a good predictor of response, and the last left ventricular (LV) segment to contract can influence the response.

OBJECTIVES

To assess electromechanical dyssynchrony in CRT with LV lead implantation guided by GATED SPECT.

METHODS

This study included 15 patients with functional class II-IV HF and clinically optimized, ejection fraction of 35%, sinus rhythm, left bundle-branch block, and QRS ≥ 120 ms. The patients underwent electrocardiography, answered the Minnesota Living with Heart Failure Questionnaire (MLHFQ), and underwent gated myocardial perfusion SPECT up to 4 weeks before CRT, being reassessed 6 months later. The primary analysis aimed at determining the proportion of patients with a reduction in QRS duration and favorable response to CRT, depending on concordance of the LV lead position, using chi-square test. The pre- and post-CRT variables were analyzed by use of Student t test, adopting the significance level of 5%.

RESULTS

We implanted 15 CRT devices, and 2 patients died during follow-up. The durations of the QRS (212 ms vs 136 ms) and the PR interval (179 ms vs 126 ms) were significantly reduced (p < 0.001). In 54% of the patients, the lead position was concordant with the maximal delay site. In the responder group, the lateral position was prevalent. The MLHFQ showed a significant improvement in quality of life (p < 0.0002).

CONCLUSION

CRT determines improvement in the quality of life and in electrical synchronism. Electromechanical synchronism relates to response to CRT. Positioning the LV lead in the maximal delay site has limitations.

Для цитирования: Nascimento Erivelton Alessandro do, Reis Christiane Cigagna Wiefels, Ribeiro Fernanda Baptista, Alves Christiane Rodrigues, Silva Eduardo Nani, Ribeiro Mario Luiz, Mesquita Claudio Tinoco. Relationship of Electromechanical Dyssynchrony in Patients Submitted to CRT With LV Lead Implantation Guided by Gated Myocardial Perfusion Spect.. Arquivos brasileiros de cardiologia. 2018. DOI: 10.5935/abc.20180159.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.