MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2018.04.011

Медицинская библиотека · JACC. Cardiovascular interventions · 2018

Immediate Post-Procedural 12-Lead Electrocardiography as Predictor of Late Conduction Defects After Transcatheter Aortic Valve Replacement.

Jørgensen Troels H, De Backer Ole, Gerds Thomas A, Bieliauskas Gintautas, Svendsen Jesper H, Søndergaard Lars

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to use a 12-lead electrocardiogram obtained immediately post-transcatheter aortic valve replacement (TAVR) to identify predictors of late high-degree conduction defect (HD-CD) within 30 days after TAVR.

BACKGROUND

There are limited data on risk factors for the development of late HD-CD and the need to retain the temporary pacemaker after TAVR.

METHODS

A single-center study was conducted including 467 consecutive patients, without pre-procedural pacemakers, undergoing TAVR.

RESULTS

Self-expandable, mechanical, or balloon-expandable heart valves were implanted in 328 (70%), 61 (13%), and 78 (17%) patients, respectively. For patients in sinus rhythm without right bundle branch block, late HD-CD developed in 0 of 70 patients (0%; 95% confidence interval [CI]: 0% to 5.1%) with PR interval <200 ms and QRS interval <120 ms and in 5 of 109 patients (4.6%; 95% CI: 1.5% to 10.4%; all with sufficient escape rhythm) with PR interval <240 ms and QRS interval <150 ms. Late HD-CD developed in 14 of 101 patients (13.9%; 95% CI: 7.8% to 22.2%; 6 with insufficient escape rhythm [5.9%; 95% CI: 2.2% to 12.5%]) with PR interval ≥240 ms or QRS interval ≥150 ms. Furthermore, late HD-CD developed in 3 of 49 patients (6.1%; 95% CI: 1.3% to 16.9%; all with sufficient escape rhythm) and in 3 of 30 patients (10.0%; 95% CI: 2.1% to 26.5%; 2 with insufficient escape rhythm [6.7%; 95% CI: 0.8% to 22.1%]) with atrial fibrillation and no right bundle branch block with QRS interval <140 and ≥140 ms, respectively.

CONCLUSIONS

On the basis of immediate post-TAVR 12-lead electrocardiography, removing the temporary pacemaker immediately following TAVR is potentially safe in patients without right bundle branch block who are: 1) in sinus rhythm with PR interval <240 ms and QRS interval <150 ms; or 2) in atrial fibrillation with a QRS interval <140 ms.

Для цитирования: Jørgensen Troels H, De Backer Ole, Gerds Thomas A, Bieliauskas Gintautas, Svendsen Jesper H, Søndergaard Lars. Immediate Post-Procedural 12-Lead Electrocardiography as Predictor of Late Conduction Defects After Transcatheter Aortic Valve Replacement.. JACC. Cardiovascular interventions. 2018. DOI: 10.1016/j.jcin.2018.04.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.