MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eijy14m11_11

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2016

STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised controlled trial.

Adriaenssens Tom, Ughi Giovanni J, Dubois Christophe, De Cock Dries, Onsea Kevin, Bennett Johan, Wiyono Stefanus, Sinnaeve Peter, Coosemans Mark, Ferdinande Bert, Belmans Ann, D'hooge Jan, Desmet Walter

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: To compare tissue coverage in coronary lesions stented with durable fluoropolymer-coated everolimus-eluting stents (EES) vs. biodegradable polymer-coated biolimus A9-eluting stents (BES).

METHODS AND

RESULTS

Sixty-four patients (64 lesions) with de novo coronary artery lesions were randomised to percutaneous treatment with XIENCE EES (Abbott Vascular, Santa Clara, CA, USA) vs. BioMatrix BES (Biosensors, Morges, Switzerland). The primary endpoint was the percentage of uncovered struts, as assessed with OCT, at nine months. The average percentage of uncovered struts was significantly lower with EES (4.3±4.8% vs. 8.7±7.8% with BES, p=0.019). There was no difference in the average percentage of malapposed struts at baseline (6.8±6.9% vs. 6.9±7.0%, respectively, p=0.974) and at follow-up (0.1±0.3% vs. 0.6±1.3%, p=0.143). Neointimal thickness at nine months was 109±43 µm in EES vs. 64±18 µm in BES (p<0.001), and angiographic LLL was 0.15 mm in EES vs. 0.10 mm in BES (p=0.581). We did not observe differences in the incidence of MACE and ST.

CONCLUSIONS

A significantly higher percentage of uncovered struts was detected in the BioMatrix BES compared with the XIENCE EES at nine-month follow-up. Our findings do not support a preferential use of stents with biodegradable polymer-based biolimus elution to reduce the risk for ST.

Для цитирования: Adriaenssens Tom, Ughi Giovanni J, Dubois Christophe, De Cock Dries, Onsea Kevin, Bennett Johan, Wiyono Stefanus, Sinnaeve Peter, Coosemans Mark, Ferdinande Bert, Belmans Ann, D'hooge Jan, Desmet Walter. STACCATO (Assessment of Stent sTrut Apposition and Coverage in Coronary ArTeries with Optical coherence tomography in patients with STEMI, NSTEMI and stable/unstable angina undergoing everolimus vs. biolimus A9-eluting stent implantation): a randomised controlled trial.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2016. DOI: 10.4244/eijy14m11_11.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.