MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2014.09.008

Медицинская библиотека · Journal of the American College of Cardiology · 2014

Second-generation drug-eluting stent implantation followed by 6- versus 12-month dual antiplatelet therapy: the SECURITY randomized clinical trial.

Colombo Antonio, Chieffo Alaide, Frasheri Arian, Garbo Roberto, Masotti-Centol Monica, Salvatella Neus, Oteo Dominguez Juan Francisco, Steffanon Luigi, Tarantini Giuseppe, Presbitero Patrizia, Menozzi Alberto, Pucci Edoardo, Mauri Josepa, Cesana Bruno Mario, Giustino Gennaro, Sardella Gennaro

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The optimal duration of dual antiplatelet therapy (DAPT) following second-generation drug-eluting stent (DES) implantation is still debated.

OBJECTIVES

The aim of this study was to test the noninferiority of 6 versus 12 months of DAPT in patients undergoing percutaneous coronary intervention with second-generation DES.

METHODS

The SECURITY (Second Generation Drug-Eluting Stent Implantation Followed by Six- Versus Twelve-Month Dual Antiplatelet Therapy) trial was a 1:1 randomized, multicenter, international, investigator-driven, noninferiority study conducted from July 2009 to June 2014. Patients with a stable or unstable angina diagnosis or documented silent ischemia undergoing revascularization with at least 1 second-generation DES were eligible. The primary endpoint was a composite of cardiac death, myocardial infarction (MI), stroke, definite or probable stent thrombosis, or Bleeding Academic Research Consortium (BARC) type 3 or 5 bleeding at 12 months. The main secondary endpoint was a composite of cardiac death, MI, stroke, definite or probable stent thrombosis, or BARC type 2, 3, or 5 bleeding at 12 and 24 months.

RESULTS

Overall, 1,399 patients were enrolled in the study and randomized to receive 6 months (n = 682) versus 12 months (n = 717) DAPT. The primary composite endpoint occurred, respectively, in 4.5% versus 3.7% (risk difference 0.8%; 95% confidence interval [CI]: -2.4% to 1.7%; p = 0.469) at 12 months. The upper 95% CI limit was lower than the pre-set margin of 2%, confirming the noninferiority hypothesis (p < 0.05). Moreover, no differences were observed in the occurrence of the secondary endpoint at 12 months (5.3% vs. 4.0%, difference: 1.2%; 95% CI: -1.0 to 3.4; p = 0.273) and between 12 and 24 months (1.5% vs. 2.2%, difference: -0.7%; 95% CI: -2.1 to 0.6; p = 0.289). Finally, no differences were observed in definite or probable stent thrombosis at 12 months (0.3% vs. 0.4%; difference: -0.1%; 95% CI: -0.7 to 0.4; p = 0.694) and between 12 and 24 months of follow-up (0.1% vs. 0%; difference: 0.1%; 95% CI: -0.1 to 0.4; p = 0.305).

CONCLUSIONS

In a low-risk population, the noninferiority hypothesis of 6 vs. 12 months DAPT following second-generation DES implantation appears accepted for the incidence of cardiac death, MI, stroke, definite/probable stent thrombosis, and BARC type 3 or 5 bleeding at 12 months. (Second Generation Drug-Eluting Stent Implantation Followed by Six- Versus Twelve-Month Dual Antiplatelet Therapy; NCT00944333).

Для цитирования: Colombo Antonio, Chieffo Alaide, Frasheri Arian, Garbo Roberto, Masotti-Centol Monica, Salvatella Neus, Oteo Dominguez Juan Francisco, Steffanon Luigi, Tarantini Giuseppe, Presbitero Patrizia, Menozzi Alberto, Pucci Edoardo, Mauri Josepa, Cesana Bruno Mario, Giustino Gennaro, Sardella Gennaro. Second-generation drug-eluting stent implantation followed by 6- versus 12-month dual antiplatelet therapy: the SECURITY randomized clinical trial.. Journal of the American College of Cardiology. 2014. DOI: 10.1016/j.jacc.2014.09.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.