OBJECTIVE

To determine whether copeptin-us can rule out diagnosis of non-ST-segment elevation myocardial infarction (NSTEMI) without prolonged monitoring and serial blood sampling in patients with high-sensitive cardiac troponin I (hs-cTnI) below the 99th centile at presentation to the emergency department (ED) [corrected].

DESIGN

Prospective, non-randomised, individual blinded diagnostic accuracy study.

SETTING

Two EDs of a rural region of France.

PARTICIPANTS

Patients with chest pain suspected of NSTEMI with onset within the last 12 h were considered for enrollment.

INTERVENTIONS: Serial clinical, electrographical and biochemical investigations were performed at admission and after 2, 4, 6 and 12 h. Hs-cTnI was measured using an assay with Dimension VISTA, Siemens [corrected]. Copeptin was measured by the BRAHMS copeptin-us assay on the KRYPTOR Compact Plus system. The follow-up period was 90 days.

PRIMARY AND SECONDARY OUTCOME MEASURES: Copeptin, troponin, myoglobin and creatine kinase values. Clinical and paraclinical events. The final diagnosis was adjudicated blinded to copeptin result.

RESULTS

During 12 months, 102 patients were analysed. Final diagnosis was NSTEMI for 7.8% (n=8), unstable angina for 3.9% (n=4), cardiac but non-coronary artery disease for 8.8% (n=9), non-cardiac chest pain for 52% (n=53) and unknown for 27.5% (n=28). There was no statistical difference for copeptin values between patients with NSTEMI and others (respectively 5.5 pmol/L IQR (3.1-7.9) and 6.5 pmol/L IQR (3.9-12.1), p=0.49). Only one patient with NSTEMI had a copeptin value above the cut-off of 95th centile at admission.

CONCLUSIONS

In this study, copeptin does not add a diagnostic value at admission to ED for patients with suspected acute coronary syndrome without ST-segment elevation and with hs-cTnI below the 99th centile [corrected].

TRIAL REGISTRATION NUMBER: Clinicaltrials.gov identifier: NCT01334645.

Для цитирования: Duchenne Jonathan, Mestres Stéphanie, Dublanchet Nicolas, Combaret Nicolas, Marceau Geoffroy, Caumon Laurent, Dutoit Laurent, Ughetto Sylvie, Motreff Pascal, Sapin Vincent, Schmidt Jeannot, NSTEMI Study. Diagnostic accuracy of copeptin sensitivity and specificity in patients with suspected non-ST-elevation myocardial infarction with troponin I below the 99th centile at presentation.. BMJ open. 2014. DOI: 10.1136/bmjopen-2013-004449.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.