MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.asw.0000658588.28614.96

Медицинская библиотека · Advances in skin & wound care · 2020

Construction and Validation of an Instrument for Assessing the Feet of Persons with Diabetes.

da Costa Saulo Pereira, Chavaglia Suzel Regina Ribeiro, Ohl Rosali Isabel Barduchi, Costa Bruna Yara, Barbosa Maria Helena, Woo Kevin, Gamba Mônica Antar

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To construct and validate an assessment instrument to evaluate the feet of people with diabetes mellitus in Brazil.

METHODS

Methodological research developed in three stages: construction of the Assessment Instrument for the Feet of People with Diabetes Mellitus, validation of face and content validity, and field research with 131 participating patients. The Pearson (r) and Spearman correlation coefficients (ρ) were used for criterion validity. To test reliability, the internal consistency of the Cronbach α domains was evaluated and simple κ, weighted κ, and intraclass correlation coefficients for interobserver evaluation were determined.

RESULTS

The instrument demonstrated validity and reliability. The content validity index represented a high internal consistency (α > .70). The interclass correlation coefficient was high (>0.98). The Pearson (r) and Spearman (ρ) correlation tests confirmed a correlation between the two variables.

CONCLUSIONS

The instrument was valid and reliable for assessing the feet of people with diabetes mellitus in Brazil. Future studies should identify the cut off point for the diagnosis of neuropathic and vascular impairment of the feet of diabetic persons through appropriate statistical methods.

Для цитирования: da Costa Saulo Pereira, Chavaglia Suzel Regina Ribeiro, Ohl Rosali Isabel Barduchi, Costa Bruna Yara, Barbosa Maria Helena, Woo Kevin, Gamba Mônica Antar. Construction and Validation of an Instrument for Assessing the Feet of Persons with Diabetes.. Advances in skin & wound care. 2020. DOI: 10.1097/01.asw.0000658588.28614.96.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.