MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/ultra.33.6.1031

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2014

Acoustic radiation force impulse imaging for evaluation of the thyroid gland.

Calvete Angela Cepero, Mestre J Dios Berná, Gonzalez Jose Manuel Rodriguez, Martinez Elena Sáez, Sala Begoña Torregrosa, Zambudio Antonio Rios

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To study acoustic radiation force impulse (ARFI) imaging as a new quantitative and noninvasive tool for evaluating thyroid nodules and to compare ARFI imaging with other tools for studying thyroid nodules: sonography, real-time elastography, and fine-needle aspiration biopsy.

METHODS

We conducted a prospective study from June 2011 to June 2012, which analyzed 157 thyroid nodules (129 benign and 28 malignant) using the ARFI technique and a 9-MHz probe. Shear wave velocities (SWVs) were obtained while the patients held their breath to avoid respiratory movement artifacts. All nodules underwent conventional sonography and real-time elastography of the thyroid gland. All patients received either a cytologic examination using fine-needle aspiration biopsy or a histologic examination from thyroid surgery to verify the diagnosis (reference standard).

RESULTS

The mean SWV ± SD on ARFI imaging in healthy, nodule-free thyroid glands was 2.04 ± 0.51 m/s (range, 0.76-3.63 m/s). The mean SWV in benign thyroid nodules was 1.70 ± 0.55 m/s (range, 0.50-2.80 m/s), and the mean SWV in malignant nodules was 3.39 ± 1.15 m/s (range, 1.50-6.08 m/s). When we used an SWV greater than 2.50 m/s for the diagnosis of malignant nodules and less than 2.50 m/s for the diagnosis of benign nodules, the sensitivity and specificity of ARFI imaging were 85.7% and 96.0%, respectively.

CONCLUSIONS

We found that SWVs were substantially higher in malignant nodules than benign ones. Perhaps if ARFI imaging is used in conjunction with sonographic findings and patient demographics, it will be possible to find a combination of factors that would yield a negative predictive value high enough to distinguish benign from malignant nodules with confidence, which may lead to a decrease in the biopsy rate for benign nodules.

Для цитирования: Calvete Angela Cepero, Mestre J Dios Berná, Gonzalez Jose Manuel Rodriguez, Martinez Elena Sáez, Sala Begoña Torregrosa, Zambudio Antonio Rios. Acoustic radiation force impulse imaging for evaluation of the thyroid gland.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2014. DOI: 10.7863/ultra.33.6.1031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.