Myocardial Arterial Spin Labeling with Double Inversion Recovery for reduced physiological noise.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Božić-Iven Maša, Rapacchi Stanislas, Zhang Yi, Tao Qian, Schad Lothar Rudi, Weingärtner Sebastian
Аннотация
PURPOSE: To introduce Double Inversion Recovery (DIR) preparations for myocardial Arterial Spin Labeling (myoASL) for mitigation of heart rate (HR) variability induced physiological noise (PN).
METHODS: DIR-labeling was implemented for double ECG-gated myoASL-sequences and compared with conventional Flow-sensitive Alternating Inversion Recovery (FAIR) labeling using single inversions. In DIR-preparations, the FAIR-inversion pulses were immediately followed by an identical reinversion pulse, applied either slice-selectively or nonselectively. Bloch-equation-based simulation and phantom experiments were performed to evaluate the PN and SNR across a range of HR variabilities. Data from six healthy subjects were acquired to evaluate myocardial blood flow (MBF), PN, and SNR in vivo.
RESULTS: Simulation experiments showed that the average MBF values remained nearly constant across the range of HR variabilities and were comparable across all three sequences. However, DIR-labeling allowed for greater recovery of the myocardial background signal, which mitigates the sensitivity to HR-dependent changes in the inversion time. Consequently, PN in the presence of HR variability was substantially reduced with DIR-labeling. For HR variabilities corresponding to the mean value observed in vivo, this resulted in a simulated SNR gain of 1.79 ± $$ \pm $$ 0.90 for selective and 1.55 ± $$ \pm $$ 0.77 for nonselective DIR-labeling. In vivo, DIR-labeling showed reduced PN, with 53% ( p < 0 . 05 $$ p<0.05 $$ )/44% ( p = 0 . 16 $$ p=0.16 $$ ) less PN compared with conventional FAIR-myoASL, leading to an average SNR gain of 1.47 ± $$ \pm $$ 0.63 ( p = 0 . 09 $$ p=0.09 $$ )/1.32 ± $$ \pm $$ 0.57 ( p = 0 . 84 $$ p=0.84 $$ ) with selective/nonselective reinversions.
CONCLUSION: The proposed DIR-preparations reduce sensitivity to HR variations and alleviate PN in double ECG-gated myoASL, improving the precision of myoASL-based perfusion quantification.
METHODS: DIR-labeling was implemented for double ECG-gated myoASL-sequences and compared with conventional Flow-sensitive Alternating Inversion Recovery (FAIR) labeling using single inversions. In DIR-preparations, the FAIR-inversion pulses were immediately followed by an identical reinversion pulse, applied either slice-selectively or nonselectively. Bloch-equation-based simulation and phantom experiments were performed to evaluate the PN and SNR across a range of HR variabilities. Data from six healthy subjects were acquired to evaluate myocardial blood flow (MBF), PN, and SNR in vivo.
RESULTS: Simulation experiments showed that the average MBF values remained nearly constant across the range of HR variabilities and were comparable across all three sequences. However, DIR-labeling allowed for greater recovery of the myocardial background signal, which mitigates the sensitivity to HR-dependent changes in the inversion time. Consequently, PN in the presence of HR variability was substantially reduced with DIR-labeling. For HR variabilities corresponding to the mean value observed in vivo, this resulted in a simulated SNR gain of 1.79 ± $$ \pm $$ 0.90 for selective and 1.55 ± $$ \pm $$ 0.77 for nonselective DIR-labeling. In vivo, DIR-labeling showed reduced PN, with 53% ( p < 0 . 05 $$ p<0.05 $$ )/44% ( p = 0 . 16 $$ p=0.16 $$ ) less PN compared with conventional FAIR-myoASL, leading to an average SNR gain of 1.47 ± $$ \pm $$ 0.63 ( p = 0 . 09 $$ p=0.09 $$ )/1.32 ± $$ \pm $$ 0.57 ( p = 0 . 84 $$ p=0.84 $$ ) with selective/nonselective reinversions.
CONCLUSION: The proposed DIR-preparations reduce sensitivity to HR variations and alleviate PN in double ECG-gated myoASL, improving the precision of myoASL-based perfusion quantification.