MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/eurheartj/14.3.369

Медицинская библиотека · European heart journal · 1993

Left ventricular diastolic filling alterations in subjects with mitral valve prolapse: a Doppler echocardiographic study.

Corrao S, Scaglione R, Arnone S, Licata G

СтатьяПеревод пока не подготовлен

Аннотация

To assess left ventricular diastolic filling in mitral valve prolapse (MVP), we studied 22 patients with idiopathic MVP and 22 healthy controls matched for sex, age, body surface area and heart rate. A two-dimensional, M-mode and Doppler echocardiographic examination was performed to exclude any cardiac abnormalities. The two groups had similar diastolic and systolic left ventricular volumes, left ventricle mass and ejection fraction. Doppler measurements of mitral inflow were: E and A areas (the components of the total flow velocity-time integral in the early passive period of ventricular filling, E; and the late active period of atrial emptying, A), the peak E and A velocities (cm.s-1), acceleration and deceleration half-times (ms) of early diastolic rapid inflow, acceleration time of early diastolic flow (AT), total diastolic filling time (DFT) (ms), and the deceleration of early diastolic flow (cm.s-2). From these measurements were calculate: peak A/E ratio (A/E), E area/A area, the early filling fraction, the atrial filling fraction, AT/DFT ratio. All the Doppler measurements reported are the average of three cardiac cycles selected at end expiration. The mean peak A velocity, A/E velocity ratio, deceleration half time and atrial filling fraction were each significantly higher for subjects presenting a MVP (60 +/- 12 cm.s-1 vs 49 +/- 14, P < 0.008; 98 +/- 13% vs 64 +/- 12%, P < 0.0001; 120 +/- 36 ms vs 92 +/- 11, P < 0.002; 0.45 +/- 0.14 vs 0.36 +/- 0.08, P < 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Corrao S, Scaglione R, Arnone S, Licata G. Left ventricular diastolic filling alterations in subjects with mitral valve prolapse: a Doppler echocardiographic study.. European heart journal. 1993. DOI: 10.1093/eurheartj/14.3.369.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.