MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2022.04.018

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2022

Analysis of diaphragm movements to specify geometric uncertainties of respiratory gating near end-exhalation for irradiation fields involving the liver dome.

Tony Liang Hsiang-Kuang, Takei Hideyuki, Tomita Tetsuya, Terunuma Toshiyuki, Isobe Tomonori, Okumura Toshiyuki, Sakae Takeji, Sakurai Hideyuki

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: The technique of gating near end-exhalation is commonly adopted to reduce respiration-associated geometric uncertainties for particle beam therapy. However, for irradiation fields involving the liver dome, how diaphragm movements generating liver-lung interface change, alongside geometric uncertainties, remain unspecified.

METHODS AND MATERIALS: Patients receiving respiratory-gated computed tomography (RGCT) with four-dimensional computed tomography (4DCT) scans during simulation were retrospectively reviewed. Differences (Δ) between RGCT and 4DCT images, including diaphragm displacements and liver-lung interface changes, were investigated to specify geometric uncertainties during early inhalation phases. Craniocaudal displacements (Δy, in sagittal/coronal planes) of diaphragm segments (dorsal/ventral/right lateral/medial), liver area changes (ΔA, in axial planes), and liver extent changes in specific directions of incidence (Δr, in axial planes) were analyzed.

RESULTS

Altogether, 162 patients received simulating RGCT and 4DCT scans. In 22 of them, both images involved the liver dome. For most cases during early inhalation phases, the Δy values in the dorsal diaphragm were significantly greater than those in the ventral diaphragm (p < 0.05), the ΔA values were significantly enlarged with inhalation progressing (p < 0.05), and the Δr values in the dorsal direction were significantly larger than those in the ventral direction (p < 0.05). These results suggested that the dorsal diaphragm moves earlier and more in a caudal direction than the ventral diaphragm during early inhalation phases.

CONCLUSIONS

For respiratory-gated radiotherapy near end-exhalation and irradiation fields involving the liver dome, components of geometric uncertainties are temporospatial, including diaphragm segment movements, inhalation phases of irradiation, and beam angles of incidence.

Для цитирования: Tony Liang Hsiang-Kuang, Takei Hideyuki, Tomita Tetsuya, Terunuma Toshiyuki, Isobe Tomonori, Okumura Toshiyuki, Sakae Takeji, Sakurai Hideyuki. Analysis of diaphragm movements to specify geometric uncertainties of respiratory gating near end-exhalation for irradiation fields involving the liver dome.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2022. DOI: 10.1016/j.radonc.2022.04.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.