m+Medelevator.RU
← Поиск публикаций
Journal of clinical microbiology · 2020

Retrospective Review of Clinical Utility of Shotgun Metagenomic Sequencing Testing of Cerebrospinal Fluid from a U.S. Tertiary Care Medical Center.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rodino Kyle G, Toledano Michel, Norgan Andrew P, Pritt Bobbi S, Binnicker Matthew J, Yao Joseph D, Aksamit Allen J, Patel Robin

Аннотация

Shotgun metagenomic sequencing can detect nucleic acids from bacteria, fungi, viruses, and/or parasites in clinical specimens; however, little data exist to guide its optimal application to clinical practice. We retrospectively reviewed results of shotgun metagenomic sequencing testing requested on cerebrospinal fluid samples submitted to an outside reference laboratory from December 2017 through December 2019. Of the 53 samples from Mayo Clinic patients, 47 were requested by neurologists, with infectious diseases consultation in 23 cases. The majority of patients presented with difficult-to-diagnose subacute or chronic conditions. Positive results were reported for 9 (17%) Mayo Clinic patient samples, with 6 interpreted as likely contamination. Potential pathogens reported included bunyavirus, human herpesvirus 7, and enterovirus D-68, ultimately impacting care in two cases. Twenty-seven additional samples were submitted from Mayo Clinic Laboratories reference clients, with positive results reported for three (11%): two with potential pathogens (West Nile virus and Toxoplasma gondii) and one with Streptococcus species with other bacteria below the reporting threshold (considered to represent contamination). Of 68 negative results, 10 included comments on decreased sensitivity due to high DNA background (n = 5), high RNA background (n = 1), insufficient RNA read depth (n = 3), or quality control (QC) failure with an external RNA control (n = 1). The overall positive-result rate was 15% (12/80), with 58% (7/12) of these interpreted as being inconsistent with the patient's clinical presentation. Overall, potential pathogens were found in a low percentage of cases, and positive results were often of unclear clinical significance. Testing was commonly employed in cases of diagnostic uncertainty and when immunotherapy was being considered.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты