MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultras.2026.108150

Медицинская библиотека · Ultrasonics · 2026

Acoustics-catalyzed e-tongues for high-performance detection and identification of sweat metabolites.

Huang Huiyu, Yin Jia, Yang Quanquan, Zhang Shuo, Chen Zhong, Lin Yuyang, Tang Qiang, Qi Xiaomin, Su Songfei, Chen Jinyan, Qu Shengling, Liu Pengzhan, Hu Junhui

СтатьяПеревод пока не подготовлен

Аннотация

The capability for high-precision detection and identification of sweat metabolites is of great importance for personalized healthcare, disease monitoring, and early management of health risks. In this study, we develop an acoustics-catalyzed e-tongue (ACET), which compactly integrates an ultrasonic actuation unit with a biosensor unit based on the oxygen reduction reaction mechanism, enabling substantially enhanced sweat metabolite detection and identification compared with the standalone biosensor unit. Owing to the synergistic effects of ultrasonic excitation and the accompanying acoustofluidic effects, the steady-state response of the biosensor is experimentally improved by up to one order of magnitude (10 × ), while the limit of detection is reduced by as much as 80% through ultrasonic catalysis. Moreover, a unique metabolite identification strategy is proposed for the ACET, achieving a 100% success rate for metabolite-type identification of NaCl and KCl under high-concentration conditions with strong ultrasonic excitation. Beyond its outstanding performance in sweat metabolite detection and identification, which is highly attractive for healthcare management, the ACET provides a robust and versatile platform for physically enhancing electrochemical reactions through ultrasonic catalysis, holding strong potential for a broad range of biosensing applications.

Для цитирования: Huang Huiyu, Yin Jia, Yang Quanquan, Zhang Shuo, Chen Zhong, Lin Yuyang, Tang Qiang, Qi Xiaomin, Su Songfei, Chen Jinyan, Qu Shengling, Liu Pengzhan, Hu Junhui. Acoustics-catalyzed e-tongues for high-performance detection and identification of sweat metabolites.. Ultrasonics. 2026. DOI: 10.1016/j.ultras.2026.108150.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.