Development and validation of a lateral flow immunoassay for rapid detection of VanA-producing enterococci.

Oueslati Saoussen, Volland Hervé, Cattoir Vincent, Bernabeu Sandrine, Girlich Delphine, Dulac Ducan, Plaisance Marc, Laroche Maxime, Dortet Laurent, Simon Stéphanie, Naas Thierry

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

VRE are nosocomial pathogens with an increasing incidence in recent decades. Rapid detection is crucial to reduce their spread and prevent infections and outbreaks.

OBJECTIVES

To evaluate a lateral flow immunoassay (LFIA) (called NG-Test VanA) for the rapid and reliable detection of VanA-producing VRE (VanA-VRE) from colonies and broth.

METHODS

NG-Test VanA was validated on 135 well-characterized enterococcal isolates grown on Mueller-Hinton (MH) agar (including 40 VanA-VRE). Different agar plates and culture broths widely used in routine laboratories for culture of enterococci were tested.

RESULTS

All 40 VanA-VRE clinical isolates were correctly detected in less than 15 min irrespective of the species expressing the VanA ligase and the medium used for bacterial growth. No cross-reaction was observed with any other clinically relevant ligases (VanB, C1, C2, D, E, G, L, M and N). Overall, the sensitivity and specificity of the assay were 100% for VanA-VRE grown on MH agar plates. NG-Test VanA accurately detects VanA-VRE irrespective of the culture medium (agar and broth). Band intensity was increased when using bacteria grown on vancomycin-containing culture media or on MH close to the vancomycin disc as a consequence of VanA induction. The limit of detection of the assay was 6.3 × 106 cfu per test with bacteria grown on MH plates and 4.9 × 105 cfu per test with bacteria grown on ChromID® VRE plates.

CONCLUSIONS

NG-Test VanA is efficient, rapid and easy to implement in the routine workflow of a clinical microbiology laboratory for the confirmation of VanA-VRE.

Для цитирования: Oueslati Saoussen, Volland Hervé, Cattoir Vincent, Bernabeu Sandrine, Girlich Delphine, Dulac Ducan, Plaisance Marc, Laroche Maxime, Dortet Laurent, Simon Stéphanie, Naas Thierry. Development and validation of a lateral flow immunoassay for rapid detection of VanA-producing enterococci.. The Journal of antimicrobial chemotherapy. 2021. DOI: 10.1093/jac/dkaa413.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.