MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/liv.12916

Медицинская библиотека · Liver international : official journal of the International Association for the Study of the Liver · 2015

Liver stiffness plus platelet count can be used to exclude high-risk oesophageal varices.

Ding Nik S, Nguyen Tin, Iser David M, Hong Thai, Flanagan Emma, Wong Avelyn, Luiz Lauren, Tan Jonathan Y C, Fulforth James, Holmes Jacinta, Ryan Marno, Bell Sally J, Desmond Paul V, Roberts Stuart K, Lubel John, Kemp William, Thompson Alexander J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Endoscopic screening for high-risk gastro-oesophageal varices (GOV) is recommended for compensated cirrhotic patients with transient elastography identifying increasing numbers of patients with cirrhosis without portal hypertension. Using liver stiffness measurement (LSM) ± platelet count, the aim was to develop a simple clinical rule to exclude the presence of high-risk GOV in patients with Child-Pugh A cirrhosis.

METHODS

A retrospective analysis of 71 patients with Child-Pugh A cirrhosis diagnosed by transient elastography (LSM >13.6 kPa) who underwent screening gastroscopy was conducted. A predictive model using LSM ± platelet count was assessed to exclude the presence of high-risk GOV (diameter >5 mm and/or the presence of high-risk stigmata) and validated using a second cohort of 200 patients from two independent centres.

RESULTS

High-risk GOV were present in 10 (15%) and 16 (8%) of the training and validation cohorts, respectively, which was associated with LSM and Pl count (P < 0.05). A combined model based on LSM and Pl count was more accurate for excluding the presence of high-risk GOV than either alone (training cohort AUROC: 0.87 [0.77-0.96] vs. 0.78 [0.65-0.92] for LSM and 0.71 [0.52-0.90] for platelets) with the combination of LSM ≤25 kPa and Pl ≥100 having a NPV of 100% in both the training and validation cohorts. A total of 107 (39%) patients meet this criterion.

CONCLUSION

The combination of LSM ≤25 kPa and Pl ≥100 can be used in clinical practice to exclude the presence of high-risk GOV in patients with Child-Pugh A cirrhosis.

Для цитирования: Ding Nik S, Nguyen Tin, Iser David M, Hong Thai, Flanagan Emma, Wong Avelyn, Luiz Lauren, Tan Jonathan Y C, Fulforth James, Holmes Jacinta, Ryan Marno, Bell Sally J, Desmond Paul V, Roberts Stuart K, Lubel John, Kemp William, Thompson Alexander J. Liver stiffness plus platelet count can be used to exclude high-risk oesophageal varices.. Liver international : official journal of the International Association for the Study of the Liver. 2015. DOI: 10.1111/liv.12916.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.