DOI 10.1007/s00266-023-03382-3
Modified Levator Resection Technique for Moderate Congenital Blepharoptosis.
Аннотация
BACKGROUND
For moderate ptosis associated with fair levator function (LF), the levator resection is the most commonly used procedure. However, the levator resection technique still has some disadvantages, such as residual lagophthalmos (RL), undercorrection, conjunctival prolapse, and eyelid contour abnormality. To solve the above problems, our team have made modifications to the levator resection technique in three aspects: releasing the levator muscle sufficiently, preserving the supporting structure of the conjunctiva, and placing multiple suture sites.
METHODS
Fifty-seven patients (81 eyes) underwent the modified levator resection technique and were enrolled in the study. Preoperative data collected included age, sex, margin reflex distance 1 (MRD1), and LF. Postoperative data collected included MRD1, RL, patient satisfaction, complications, and length of follow-up.
RESULTS
Mean MRD1 significantly increased from 1.45 ± 0.65 mm preoperatively to 3.57 ± 0.51 mm postoperatively. Mean LF significantly increased from 6.49 ± 1.12 mm preoperatively to 9.48 ± 1.39 mm postoperatively. Successful correction was obtained in 77 eyes (95.1%). Mean RL was 1.09 ± 0.57 and 72 eyes (88.9%) showed excellent or good eyelid closure function. Fifty-four patients (94.7%) were completely satisfied with the final result. Complications such as hematoma, infection, conjunctival prolapse, suture exposure, corneal abrasion, and keratitis were not found in any cases during follow-up.
CONCLUSION
This modified levator resection technique introduced in this study is effective in correcting moderate congenital blepharoptosis, while minimizing RL, undercorrection, conjunctival prolapse, eyelid contour abnormality by releasing the levator muscle sufficiently, preserving the supporting structure of the conjunctiva, and placing multiple suture sites.
LEVEL OF EVIDENCE IV: This journal requires that authors 42 assign a level of evidence to each article. For a full 43 description of these Evidence-Based Medicine ratings, 44 please refer to the Table of Contents or the online 45 Instructions to Authors www.springer.com/00266 .