A semi-automated "blanket" method for renal segmentation from non-contrast T1-weighted MR images.
СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Rusinek Henry, Lim Jeremy C, Wake Nicole, Seah Jas-mine, Botterill Elissa, Farquharson Shawna, Mikheev Artem, Lim Ruth P
Аннотация
OBJECTIVE: To investigate the precision and accuracy of a new semi-automated method for kidney segmentation from single-breath-hold non-contrast MRI.
MATERIALS AND METHODS: The user draws approximate kidney contours on every tenth slice, focusing on separating adjacent organs from the kidney. The program then performs a sequence of fully automatic steps: contour filling, interpolation, non-uniformity correction, sampling of representative parenchyma signal, and 3D binary morphology. Three independent observers applied the method to images of 40 kidneys ranging in volume from 94.6 to 254.5 cm(3). Manually constructed reference masks were used to assess accuracy.
RESULTS: The volume errors for the three readers were: 4.4% ± 3.0%, 2.9% ± 2.3%, and 3.1% ± 2.7%. The relative discrepancy across readers was 2.5% ± 2.1%. The interactive processing time on average was 1.5 min per kidney.
CONCLUSIONS: Pending further validation, the semi-automated method could be applied for monitoring of renal status using non-contrast MRI.
MATERIALS AND METHODS: The user draws approximate kidney contours on every tenth slice, focusing on separating adjacent organs from the kidney. The program then performs a sequence of fully automatic steps: contour filling, interpolation, non-uniformity correction, sampling of representative parenchyma signal, and 3D binary morphology. Three independent observers applied the method to images of 40 kidneys ranging in volume from 94.6 to 254.5 cm(3). Manually constructed reference masks were used to assess accuracy.
RESULTS: The volume errors for the three readers were: 4.4% ± 3.0%, 2.9% ± 2.3%, and 3.1% ± 2.7%. The relative discrepancy across readers was 2.5% ± 2.1%. The interactive processing time on average was 1.5 min per kidney.
CONCLUSIONS: Pending further validation, the semi-automated method could be applied for monitoring of renal status using non-contrast MRI.
Предметные рубрики MeSH
AdultAlgorithmsContrast MediaDiabetes Mellitus, Type 2Diabetic NephropathiesDiffusion Magnetic Resonance ImagingFemaleHumansImage EnhancementImage Interpretation, Computer-AssistedKidneyMaleMiddle AgedObserver VariationOrgan SizePattern Recognition, AutomatedReproducibility of ResultsSensitivity and SpecificityUser-Computer Interface