MedElevator Войти в исследования
← Поиск публикаций

DOI 10.14503/thij-22-8048

Медицинская библиотека · Texas Heart Institute journal · 2023

Clinical Impact of Patient-Prosthesis Mismatch After Aortic Valve Replacement With a Mechanical or Biological Prosthesis.

Matkovic Milos, Aleksic Nemanja, Bilbija Ilija, Antic Ana, Lazovic Jelena Milin, Cubrilo Marko, Milojevic Aleksandar, Zivkovic Igor, Putnik Svetozar

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Patient-prosthesis mismatch (PPM) may impair functional capacity and survival after aortic valve replacement. This study aimed to investigate the impact of PPM on long-term survival and quality of life after mechanical and biological aortic valve replacement.

METHODS

This study included 595 consecutive patients who had undergone isolated aortic valve replacement. Patients were divided into 2 groups according to prosthesis type. The baseline and operative characteristics, survival rates, complications, and quality of life of the groups with and without PPM were compared for up to 6 years. The PPM calculation was performed using the effective orifice area value provided by the manufacturer divided by the patient's body surface area.

RESULTS

The moderate to severe PPM rates were 69.8% and 3.7% after biological and mechanical prosthesis implantation, respectively. Mean survival for patients in the biological group who had PPM was statistically significantly shorter (50.2 months [95% CI, 45.2-55.3]) than for patients in the biological group without PPM (60.1 months [95% CI, 55.7-64.4]; P = .04). In the mechanical prosthesis group, there was no difference in mean survival between the subgroup with PPM (66.6 months [95% CI, 58.3-74.9]) and the subgroup without PPM (64.9 months [95% CI, 62.6-67.2]; P = .50). A quality-of-life questionnaire's scores did not differ between the groups.

CONCLUSION

Mismatch is common after biological valve implantation and statistically significantly affects long-term survival and quality of life. If the risk of PPM after implantation of a biological prosthesis is suspected, adopting strategies to avoid PPM at the time of surgery is warranted.

Для цитирования: Matkovic Milos, Aleksic Nemanja, Bilbija Ilija, Antic Ana, Lazovic Jelena Milin, Cubrilo Marko, Milojevic Aleksandar, Zivkovic Igor, Putnik Svetozar. Clinical Impact of Patient-Prosthesis Mismatch After Aortic Valve Replacement With a Mechanical or Biological Prosthesis.. Texas Heart Institute journal. 2023. DOI: 10.14503/thij-22-8048.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.