MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2023.09.010

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2023

Doppler Echocardiographic Phenotypes in Suspected 'Severe' Aortic Stenosis: Matrix-Based Approach to Diagnosis and Management.

Marcus Richard H, Hamilton Russell, Ugwu Justin, Ahsan Muhammad Junaid, Tindall Scott, Narang Akhil, Lang Roberto M

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Among patients with suspected severe aortic stenosis (AS), Doppler echocardiographic (DE) data are often discordant, and further analysis is required for accurate diagnosis and optimal management. In this study, an automated matrix-based approach was applied to an echocardiographic database of patients with AS that identified 5 discrete echocardiographic data patterns, 1 concordant and 4 discordant, each reflecting a particular pathophysiology/measurement error that guides further workup and management.

METHODS

A primary/discovery cohort of consecutive echocardiographic studies with at least 1 DE parameter of severe AS and analogous data from an independent secondary/validation cohort were retrospectively analyzed. Parameter thresholds for inclusion were aortic valve area (AVA) <1.0 cm2, transaortic mean gradient (MG) ≥ 40 mmHg, and/or transaortic peak velocity (PV) ≥ 4.0 m/sec. Doppler velocity index (DVI) was also determined. Logic provided by an in-line SQL query embedded within the database was used to assign each patient to 1 of 5 discrete matrix patterns, each reflecting 1 or more specific pathophysiologies. Feasibility of automated pattern-driven triage of discordant cases was also evaluated.

RESULTS

In both cohorts, data from each patient fitted only 1 data pattern. Of the 4,643 primary cohort patients, 39% had concordant parameters for severe AS and DVI <0.30 (pattern 1); 35% had AVA < 1.0 cm2, MG < 40 mm Hg, PV < 4 m/sec, DVI < 0.30 (pattern 2); 9% had MG ≥ 40 mmHg and/or PV ≥ 4 m/sec, DVI > 0.30 (pattern 3); 10% had AVA < 1.0 cm2, MG < 40 mmHg, PV < 4 m/sec, DVI >0.30 (pattern 4); and 7% had MG > 40 mmHg and/or PV ≥ 4 m/sec, AVA > 1.0 cm2, DVI < 0.30 (pattern 5). Findings were validated among the 387 secondary cohort patients in whom pattern distribution was remarkably similar.

CONCLUSIONS

Matrix-based pattern recognition permits automated in-line identification of specific pathophysiology and/or measurement error among patients with suspected severe AS and discordant DE data.

Для цитирования: Marcus Richard H, Hamilton Russell, Ugwu Justin, Ahsan Muhammad Junaid, Tindall Scott, Narang Akhil, Lang Roberto M. Doppler Echocardiographic Phenotypes in Suspected 'Severe' Aortic Stenosis: Matrix-Based Approach to Diagnosis and Management.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2023. DOI: 10.1016/j.echo.2023.09.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.