MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1515/cclm-2022-0661

Медицинская библиотека · Clinical chemistry and laboratory medicine · 2022

Application of ultrasensitive assay for SARS-CoV-2 antigen in nasopharynx in the management of COVID-19 patients with comorbidities during the peak of 2022 Shanghai epidemics in a tertiary hospital.

Wang Di, Lu Hailong, Li Yaju, Shen Jiazhen, Jiang Guangjie, Xiang Jin, Qin Huanhuan, Guan Ming

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Various comorbidities associated with COVID-19 add up in severity of the disease and obviously prolonged the time for viral clearance. This study investigated a novel ultrasensitive MAGLUMI® SARS-CoV-2 Ag chemiluminescent immunoassay assay (MAG-CLIA) for diagnosis and monitoring the infectivity of COVID-19 patients with comorbid conditions during the pandemic of 2022 Shanghai.

METHODS

Analytical performances of the MAG-CLIA were evaluated, including precision, limit of quantitation, linearity and specificity. Nasopharyngeal specimens from 232 hospitalized patients who were SARS-CoV-2 RT-qPCR positive and from 477 healthy donors were included. The longitudinal studies were performed by monitoring antigen concentrations alongside with RT-qPCR results in 14 COVID-19 comorbid participants for up to 22 days. The critical antigen concentration in determining virus infectivity was evaluated at the reference cycle threshold (Ct) of 35.

RESULTS

COVID-19 patients were well-identified using an optimal threshold of 0.64 ng/L antigen concentration, with sensitivity and specificity of 95.7% (95% CI: 92.2-97.9%) and 98.3% (95% CI: 96.7-99.3%), respectively, while the Wondfo LFT exhibited those of 34.9% (95% CI: 28.8-41.4%) and 100% (95% CI: 99.23-100%), respectively. The sensitivity of MAG-CLIA remained 91.46% (95% CI: 83.14-95.8%) for the samples with Ct values between 35 and 40. Close dynamic consistence was observed between MAG-CLIA and viral load time series in the longitudinal studies. The critical value of 8.82 ng/L antigen showed adequate sensitivity and specificity in evaluating the infectivity of hospitalized convalescent patients with comorbidities.

CONCLUSIONS

The MAG-CLIA SARS-CoV-2 Ag detection is an effective and alternative approach for rapid diagnosis and enables us to evaluate the infectivity of hospitalized convalescent patients with comorbidities.

Для цитирования: Wang Di, Lu Hailong, Li Yaju, Shen Jiazhen, Jiang Guangjie, Xiang Jin, Qin Huanhuan, Guan Ming. Application of ultrasensitive assay for SARS-CoV-2 antigen in nasopharynx in the management of COVID-19 patients with comorbidities during the peak of 2022 Shanghai epidemics in a tertiary hospital.. Clinical chemistry and laboratory medicine. 2022. DOI: 10.1515/cclm-2022-0661.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.