MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2015.01.060

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2015

The Freedom Solo pericardial stentless valve: Single-center experience, outcomes, and long-term durability.

Stanger Olaf, Bleuel Irina, Gisler Fabian, Göber Volkhard, Reineke Sylvia, Gahl Brigitta, Aymard Thierry, Englberger Lars, Carrel Thierry, Tevaearai Hendrik

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To report our institutional experience and long-term results with the Freedom Solo bovine pericardial stentless bioprosthesis (Sorin Group, Saluggia, Italy).

METHODS

Between January 2005 and November 2009, 149 patients (mean age, 73.6 ± 8.7 years; 68 [45.6%] female) underwent isolated (n = 75) or combined (n = 74) aortic valve replacement (AVR) using the Solo in our institution. Follow-up was 100% complete with an average follow-up time of 5.9 ± 2.6 years (maximum, 9.6 years) and a total of 885.3 patient years.

RESULTS

Operative (30-day) mortality was 2.7% (1.3% for isolated AVR [n = 1] and 4.0% for combined procedures [n = 3]). All causes of death were not valve-related. Preoperative peak (mean) gradients of 74.2 ± 23.0 mm Hg (48.6 ± 16.3 mm Hg) decreased to 15.6 ± 5.4 mm Hg (8.8 ± 3.0 mm Hg) after AVR, and remained low for up to 9 years. The postoperative effective orifice area was 1.6 ± 0.57 cm(2), 1.90 ± 0.45 cm(2), 2.12 ± 0.48 cm(2), and 2.20 ± 0.66 cm(2) for the valve sizes 21, 23, 25, and 27, respectively, with absence of severe prosthesis-patient mismatch and 0.7% (n = 1) experienced moderate prosthesis-patient mismatch. During follow-up, 26 patients experienced structural valve deterioration (SVD) and 14 patients underwent explantation. Kaplan-Meier estimates for freedom from death, explantation, and SVD at 9 years averaged 0.57 (range, 0.47-0.66), 0.82 (range, 0.69-0.90), and 0.70 (range, 0.57-0.79), respectively.

CONCLUSIONS

The Freedom Solo stentless aortic valve is safe to implant and shows excellent early and midterm hemodynamic performance. However, SVD was observed in a substantial number of patients after only 5-6 years and the need for explantation increased markedly, suggesting low durability.

Для цитирования: Stanger Olaf, Bleuel Irina, Gisler Fabian, Göber Volkhard, Reineke Sylvia, Gahl Brigitta, Aymard Thierry, Englberger Lars, Carrel Thierry, Tevaearai Hendrik. The Freedom Solo pericardial stentless valve: Single-center experience, outcomes, and long-term durability.. The Journal of thoracic and cardiovascular surgery. 2015. DOI: 10.1016/j.jtcvs.2015.01.060.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.