MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/joic.12182

Медицинская библиотека · Journal of interventional cardiology · 2015

First experience with the new generation Edwards Sapien 3 aortic bioprosthesis: procedural results and short term outcome.

Murray Marie-Isabel, Geis Nicolas, Pleger Sven T, Kallenbach Klaus, Katus Hugo A, Bekeredjian Raffi, Chorianopoulos Emmanuel

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

TAVR has become an established treatment for severe symptomatic aortic stenosis in patients with high surgical risk. The latest generation of the balloon-expandable Edwards Sapien device, the Sapien 3, together with its new transfemoral Commander delivery system has been designed to reduce paravalvular regurgitation and vascular access site complications.

OBJECTIVES

To evaluate procedural results and short term outcome with the third generation Sapien 3 device.

METHODS

We retrospectively evaluated 125 consecutive TAVR patients and analyzed the first 51 patients in whom we implanted the new Sapien 3 device via transfemoral access.

RESULTS

In patients implanted with the Sapien 3 device significant residual paravalvular regurgitation after TAVR was virtually absent with the vast majority having none or trace postinterventional aortic regurgitation on angiography or echocardiography (92.2% and 80.4% respectively). None of the patients had more than mild paravalvular regurgitation. Major vascular access site complications or major bleeding according to the VARC II criteria were not observed in our cohort, minor vascular complications and minor bleeding occurred in 7.8% and 5.9% respectively. If vascular complications occurred, they were related to closure device failure. Thirty day outcome showed a 1.9% major stroke rate and 3.9% death rate. However, we observed a 25.5% permanent pacemaker rate in our Sapien 3 cohort.

CONCLUSIONS

Implantation of the new third generation Sapien 3 device resulted in excellent procedural and short term outcome. Significant paravalvular regurgitation was virtually absent. However, the increased rate of postinterventional pacemaker implantations needs to be analyzed in a larger cohort of patients.

Для цитирования: Murray Marie-Isabel, Geis Nicolas, Pleger Sven T, Kallenbach Klaus, Katus Hugo A, Bekeredjian Raffi, Chorianopoulos Emmanuel. First experience with the new generation Edwards Sapien 3 aortic bioprosthesis: procedural results and short term outcome.. Journal of interventional cardiology. 2015. DOI: 10.1111/joic.12182.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.