BACKGROUND

Several single-center studies have reported excellent outcomes with minimally invasive aortic valve replacement (mini-AVR). Although criticized as requiring more operative time and complexity, mini-AVR is increasingly performed. We compared contemporary outcomes and cost of mini-AVR versus conventional AVR in a multi-institutional regional cohort. We hypothesized that mini-AVR provides equivalent outcomes to conventional AVR without increased cost.

METHODS

Patient records for primary isolated AVR (2011-2013) were extracted from a regional, multi-institutional Society of Thoracic Surgeons database and stratified by conventional versus mini-AVR, performed by either partial sternotomy or right thoracotomy. To compare similar patients, a 1:1 propensity-matched cohort was performed after adjusting for surgeon; operative year; and Society of Thoracic Surgeons risk score, including age and risk factors (n = 289 in each group). Differences in outcomes and cost were analyzed.

RESULTS

A total of 1341 patients underwent primary isolated AVR, of which 442 (33%) underwent mini-AVR at 17 hospitals. Mortality, stroke, renal failure, and other major complications were equivalent between groups. Mini-AVR was associated with decreased ventilator time (5 vs 6 hours; P = .04) and decreased blood product transfusion (25% vs 32%; P = .04). A greater percentage of mini-AVR patients were discharged within 4 days of the operation (15.2% vs 4.8%; P < .001). Consequently, total hospital costs were lower in the mini-AVR group ($36,348 vs $38,239; P = .02).

CONCLUSIONS

Mortality and morbidity outcomes of mini-AVR are equivalent to conventional AVR. Mini-AVR is associated with decreased ventilator time, blood product use, early discharge, and reduced total hospital cost. In contemporary clinical practice, mini-AVR is safe and cost-effective.

Для цитирования: Ghanta Ravi K, Lapar Damien J, Kern John A, Kron Irving L, Speir Alan M, Fonner Edwin, Quader Mohammed, Ailawadi Gorav. Minimally invasive aortic valve replacement provides equivalent outcomes at reduced cost compared with conventional aortic valve replacement: A real-world multi-institutional analysis.. The Journal of thoracic and cardiovascular surgery. 2015. DOI: 10.1016/j.jtcvs.2015.01.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.