DOI 10.3390/life15091468

Медицинская библиотека · Life (Basel, Switzerland) · 2025

Comparative Efficacy of Reused Medium Cut-Off Dialyzers on Uremic Toxin and Cytokine Clearance: A Randomized Controlled Trial.

Lukkanalikitkul Eakalak, Jirayuphat Nichnan, Anutrakulchai Sirirat

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Expanded hemodialysis using medium cut-off (MCO) dialyzers effectively removes middle-molecule uremic toxins, comparable to hemodiafiltration, but their single-use designation increases the dialysis costs. This study evaluated the efficacy and safety of reusing two MCO dialyzers available in Thailand.

METHODS

In this randomized controlled trial, hemodialysis patients were assigned to receive treatment with either Theranova® 500 or Elisio® 21HX dialyzers. Each dialyzer was reprocessed using peracetic acid and reused for up to 15 sessions. Dialyzer performance was assessed by the reduction ratios (RRs) of solutes, including β2-microglobulin (β2-MG), kappa and lambda free light chains (κ-FLC, λ-FLC), and interleukin-6 (IL-6), at baseline and the 2nd, 5th, 10th, and 15th sessions.

RESULTS

Forty-eight patients were enrolled (mean age 63.6 ± 13.7 years; 62.5% male) and randomized into 2 groups with comparable baseline characteristics. RRs for β2-MG, κ-FLC, and λ-FLC were similar between the groups and declined modestly over time after dialyzer reused (β2-MG: 78.2% to 72.5% vs. 77.2% to 74.5%, κ-FLC: 64.6% to 51.3% vs. 58.9% to 49.5%, and λ-FLC: 51.2% to 46.4% vs. 49.4% to 39.2% in the Theranova® 500 and Elisio® 21HX groups, respectively). Theranova® 500 demonstrated significantly higher IL-6 clearance in the 2nd (29.9% vs. 16.0%; p = 0.018) and 5th (23.8% vs. 7.7%, p = 0.031) sessions. It also showed a non-significant trend toward lower dialyzer survival (HR 3.98; p = 0.085) and higher, though clinically acceptable, albumin loss (mean difference 0.56 g/session; p < 0.001), which decreased with reuse.

CONCLUSIONS

Both MCO dialyzers demonstrated comparable overall performance during reuse. Theranova® 500 provided better IL-6 clearance with manageable albumin loss. Implementation of high-quality dialyzer reuse protocols may optimize clinical efficacy and patient outcomes while balancing cost, accessibility, and environmental considerations.

Для цитирования: Lukkanalikitkul Eakalak, Jirayuphat Nichnan, Anutrakulchai Sirirat. Comparative Efficacy of Reused Medium Cut-Off Dialyzers on Uremic Toxin and Cytokine Clearance: A Randomized Controlled Trial.. Life (Basel, Switzerland). 2025. DOI: 10.3390/life15091468.