Long term follow up of percutaneous treatment for degenerated Mitroflow prosthesis with self-expanding transcatheter aortic valve implantation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pascual Isaac, Almendárez Marcel, Álvarez Velasco Rut, Adeba Antonio, Hernández-Vaquero Daniel, Lorca Rebeca, Díaz Rocío, Alperi Alberto, Cubero-Gallego Héctor, Rozado Jose, Morís César, Avanzas Pablo
Аннотация
BACKGROUND: The durability of aortic valve bioprosthesis and the structural valve deterioration (SVD) are could be treated with valve-in-valve (VIV) transcatheter aortic valve implantation (TAVI). This technique has been proven to be a feasible procedure with good results in selected patients. The aim of this work was to assess the long-term results of this TAVI with an autoexpandable valve in patients with failed Mitroflow (MF) bioprosthetic aortic valves.
METHODS: Single center, observational and prospective study that included 65 consecutive patients with symptomatic failed MF bioprosthetic aortic valve, treated with VIV-TAVI. The primary endpoints were clinical long-term events including all-cause mortality, cardiovascular mortality, re-hospitalization due to heart failure, stroke/transient ischemic attack (TIA) and endocarditis. Secondary endpoints were the absence of SVD or patient-prosthesis mismatch (PPM) and valve hemodynamics analysis at follow-up.
RESULTS: Between March 2012 to July 2019, 65 symptomatic patients (age 80.4±5.9 years) with degenerated MF valves (numbers 19: 27.7%; 21: 38.5%; 23: 21.5%; 25: 12.3%) underwent CoreValve (n=11) or Evolut R (n=54) implantation (23, 26 and 29 mm sizes). The STS predicted risk of mortality was 6.39%±5.62%. The primary combined endpoint occurred in 32.3% of the cases. A total of 13 patients (20%) died during follow-up, but 4 (7.3%) from cardiovascular causes. Two patients were reported of having a stroke/TIA and 5 readmissions for cardiovascular causes were reported (2 of them within the first 30 days). Twenty-five patients (38.5%) presented PPM during follow-up, being PPM severe in 15 (23.1%).
CONCLUSIONS: Self-expanding TAVI for degenerated MF bioprosthesis has favourable long-term outcomes. It is a good option in order to avoid the risks of redo surgery in selected patients.
METHODS: Single center, observational and prospective study that included 65 consecutive patients with symptomatic failed MF bioprosthetic aortic valve, treated with VIV-TAVI. The primary endpoints were clinical long-term events including all-cause mortality, cardiovascular mortality, re-hospitalization due to heart failure, stroke/transient ischemic attack (TIA) and endocarditis. Secondary endpoints were the absence of SVD or patient-prosthesis mismatch (PPM) and valve hemodynamics analysis at follow-up.
RESULTS: Between March 2012 to July 2019, 65 symptomatic patients (age 80.4±5.9 years) with degenerated MF valves (numbers 19: 27.7%; 21: 38.5%; 23: 21.5%; 25: 12.3%) underwent CoreValve (n=11) or Evolut R (n=54) implantation (23, 26 and 29 mm sizes). The STS predicted risk of mortality was 6.39%±5.62%. The primary combined endpoint occurred in 32.3% of the cases. A total of 13 patients (20%) died during follow-up, but 4 (7.3%) from cardiovascular causes. Two patients were reported of having a stroke/TIA and 5 readmissions for cardiovascular causes were reported (2 of them within the first 30 days). Twenty-five patients (38.5%) presented PPM during follow-up, being PPM severe in 15 (23.1%).
CONCLUSIONS: Self-expanding TAVI for degenerated MF bioprosthesis has favourable long-term outcomes. It is a good option in order to avoid the risks of redo surgery in selected patients.